[Icw] rated short-time withstand current | 4.65 kA ( 3 s ) 1.8 kA ( 20 s ) 1.5 kA ( 30 s ) 8 kA ( 1 s ) |
[Ue] rated operational voltage | 750 V DC 690 V AC 50/60 Hz 1000 V DC DC-20 1000 V AC 50/60 Hz AC-20 |
[Ui] rated insulation voltage | 1000 V DC 1000 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 12 kV |
Ambient air temperature for operation | -25...70 °C |
Ambient air temperature for storage | -50...85 °C |
Anvendelse | Uafbrudt |
Beregnet for hængelåse | 3 hængelåse |
Betjening | Drejehåndtag |
[Ie] rated operational current | DC-23A: 250 A DC 750 V 3 poles in series DC-23A: 250 A DC 500 V 3 poles in series DC-23A: 250 A DC 250 V 2 poles in series DC-23A: 250 A DC 125 V 2 poles in series DC-22A: 250 A DC 750 V 3 poles in series DC-22A: 250 A DC 500 V 3 poles in series DC-22A: 2 |
[Ith] conventional free air thermal current | 250 A ( 40 °C ) lodrette 250 A ( 40 °C ) power dissipation per fuse: 32 W 242 A ( 35 °C ) horizontal 237 A ( 45 °C ) vertical 230 A ( 40 °C ) vandret 225 A ( 50 °C ) lodrette 218 A ( 45 °C ) vandret 212 A ( 55 °C ) vertical 207 A ( 50 °C ) vandret 200 A ( |
[Ithe] conventional enclosed thermal current | 250 A ( 40 °C ) / Power dissipation per fuse: 23 W 600 mm x 350 mm x 300 mm 230 A ( 40 °C ) / Power dissipation per fuse: 27 W 600 mm x 350 mm x 300 mm |
Bredde | 340 mm |
Contact position indicator | Ja |
Drejehåndtag montagemetode | Direkte Udvidelse |
Dybde | 199 mm |
Egnet for adskillelse | Ja |
Elektrisk holdbarhed | AC-23A: 1000 cycles 690 V AC 50/60 Hz AC-23A: 1000 cycles 500 V AC 50/60 Hz AC-22A: 1000 cycles 690 V AC 50/60 Hz AC-22A: 1000 cycles 500 V AC 50/60 Hz |
Forureningsgrad | 3 |
Grebets farve | Black |
Handle front plate colour | Black |
Højde | 162 mm |
IK kapslingsklasse | IK10 conforming to EN 50102 IK07 conforming to EN 50102 |
Intermittedere driftsklasse | Klasse 120 - 60 % |
IP kapslingsklasse | IP65 conforming to IEC 60529 18-22 conforming to IEC 60529 |
Maximum power | 70 KW 220/240 V AC 50/60 Hz 230 kW 660/690 V AC 50/60 Hz 170 kW 500/525 V AC 50/60 Hz 140 KW 415 v AC 50/60 Hz 132 KW 380/400 V AC 50/60 Hz |
Mekanisk holdbarhed | 8000 cycles |
Montagested for drejehåndtag | Front |
Montagevejledning | Montageplade |
Netfrekvens | 50/60 Hz |
Polbeskrivelse | 4P |
Productcertificeringer | KEMA-KEUR |
Protected poles description | 3f |
Range of product | INF200...800 |
Rated making and breaking capacity | Icn 80 kA conforming to BS 415 v with fuse Icn 50 kA conforming to DIN 690 V with fuse Icn 100 kA conforming to DIN 500 V with fuse Icm 40 kA 500 V without fuse Icm 40 kA 415 v without fuse Icm 35 kA 690 V without fuse Icm 220 kA conforming to DIN 500 V w |
Sikringsafbrydernavn | INFD250 |
Sikringsstørrelse | NH0 NH1 |
Sikringstype | DIN |
Standarder | EN/IEC 60269-1 EN/IEC 60269-4 EN/IEC 60947-1 EN/IEC 60947-3 EN/IEC 60947-5 |
Tilspændingsmoment | Terminal: 30...44 N.m |
Type | AC DC |