Acti9 iC60H 1 pol 40 A Dobbelt terminal B-karakteristik 10/16 kA 230 V B:18 mm

Varenr: | A9F06140 |
El nr: | 3322062231 |
EAN13 nr: | 3606480437854 |
Pakning: | 1stk |
 |
[Ics] rated service breaking capacity | 7.5 kA 50 % x Icu conforming to IEC 60947-1 - 220...240 V AC 50/60 Hz 15 kA 50 % x Icu conforming to IEC 60947-1 - 100...133 V AC 50/60 Hz 21 kA 50 % x Icu conforming to IEC 60947-1 - 12...60 V AC 50/60 Hz 10 kA 100 % x Icu conforming to IEC 60947-1 - 12. |
[In] rated current | 40 A |
[Ue] rated operational voltage | 230/400 V AC 220...240 V AC 12...60 V AC 100...130 V AC 12...72 V DC |
[Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to IEC 60947-2 500 V AC 50/60 Hz conforming to EN 60947-2 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 6 kV conforming to EN 60947-2 |
9 mm pitches | 2 |
Ambient air temperature for operation | -35...70 °C |
Ambient air temperature for storage | -40...85 °C |
Breaking capacity | 30 kA Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 30 kA Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 42 kA Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 42 kA Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 15 kA Icu con |
Circuit breaker application | Distribution |
Colour | White |
Connections - terminals | Double terminal, top or bottom flexible wire(s) 1...25 mm˛ max Double terminal, top or bottom rigid wire(s) 1...35 mm˛ max |
Contact position indicator | Yes |
Control type | Toggle |
Curve code | B |
Depth | 78.5 mm |
Device short name | IC60H |
Earth-leakage protection | Separate block |
Electrical durability | 10000 cycles |
Height | 91 mm |
IP degree of protection | IP20 conforming to EN 60529 IP20 conforming to IEC 60529 |
Limitation class | 3 conforming to IEC 60898-1 3 conforming to EN 60898-1 |
Local signalling | Trip indicator |
Magnetic tripping limit | 4 x In +/- 20 % |
Mechanical durability | 20000 cycles |
Mounting support | DIN rail |
Network frequency | 50/60 Hz |
Network type | AC DC |
Number of protected poles | 1 |
Overvoltage category | IV |
Period | 18 months |
Poles description | 1P |
Pollution degree | 3 |
Product or component type | Circuit breaker |
Product weight | 0.125 kg |
Relative humidity | 95 % ( 55 °C ) |
Standards | EN 60898-1 EN 60947-2 IEC 60898-1 IEC 60947-2 |
Suitability for isolation | Yes conforming to IEC 60947-2 Yes conforming to IEC 60898-1 Yes conforming to EN 60947-2 Yes conforming to EN 60898-1 |
Tightening torque | 3.5 N.m top or bottom |
Trip unit technology | Thermal-magnetic |
Tropicalisation | 2 |
Utilisation category | Category A conforming to IEC 60898-1 Category A conforming to EN 60898-1 |
Width | 18 mm |
Wire stripping length | 14 mm top or bottom |
Yderliger oplysninger:
Se venligst SE katalog©Schneider Electric A/S 2025