[Us] rated supply voltage | 380...480 V (- 15...10 %) |
Accellerations- og nedreguleringsrampe | Automatic adaptation of ramp if braking capacity exceeded, by using resistor Linear adjustable separately from 0.01 to 9000 s S, U or customized |
Accuracy | AO1 +/- 1 % for a temperature variation 60 °C AI2 +/- 0.6 % for a temperature variation 60 °C AI1-/Al1+ +/- 0.6 % for a temperature variation 60 °C |
Adskillelse | Between power and control terminals |
Ambient air temperature for operation | -10...50 °C with derating factor -10...40 °C uden reducering |
Ambient air temperature for storage | -25...70 °C |
Analog indgangstype | AI2 software-configurable voltage 0...10 V DC, input spænding 24 V max, impedans 30000 Ohm, opløsning 11 bits AI2 software-configurable current 0...20 mA, impedans 242 Ohm, opløsning 11 bits AI1-/Al1+ bipolar differential voltage +/- 10 V DC, input spændi |
Analog udgangstype | AO1 software-configurable logic output 10 V, <= 20 mA AO1 software-configurable voltage, analog output udvalg 0...10 V DC, impedans 470 Ohm, opløsning 10 bits AO1 software-configurable current, analog output udvalg 0...20 mA, impedans 500 Ohm, opløsning 1 |
Analoge Indgange | 2 |
Analoge udgange | 1 |
Antal adresser | 1...247 til Modbus 1...127 til CANopen |
Antal digitale udgange | 2 |
Anvendes til | Asynchronous motors Synchronous motors |
Asynkron motorkontrol | Voltage/frequency ratio, 2 points Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f |
Beskyttelsestype | Motor thermal protection Motor power removal Motor motor fase brud Køre thermal protection Køre short-circuit between motor phases Køre power removal Køre overvoltages on the DC bus Køre over varme beskyttelse Køre overcurrent between output phases and ea |
Bredde | 315 mm |
Bremsemoment | 30 % without braking resistor <= 125 % with braking resistor |
Bremsning ved stilstand | Med DC indsprøjtning |
Dataformat | 8 bits, odd even or no configurable parity til Modbus på terminal 8 bits, 1 stop, even parity til Modbus on front face |
Dielektrisk gennemslagsholdbarhed | 5092 V DC between control and power terminals 3535 V DC between earth and power terminals |
Digital indgangslogik | LI6 (if configured as logic input) positive logic (source), < 5 V (tilstand 0), > 11 V (tilstand 1) LI6 (if configured as logic input) negative logic (sink), > 16 V (tilstand 0), < 10 V (tilstand 1) LI1...LI5 positive logic (source), < 5 V (tilstand 0), > |
Digital indgangsnummer | 7 |
Digital indgangstype | (PWR) safety input, 24 V DC, spændingsgrænser <= 30 V, impedans 1500 Ohm (LI6) switch-configurable PTC probe, 0...6, impedans 1500 Ohm (LI6) kontakt-konfiguration, 24 V DC, spændingsgrænser <= 30 V, med level 1 PLC, impedans 3500 Ohm (LI1...LI5) programme |
Digital udgangstype | (R2A, R2B) configurable relay logic No, elektrisk varighed 100000 kredsløb (R1A, R1B, R1C) configurable relay logic NO/NC, elektrisk varighed 100000 kredsløb |
Driftshøjde | 1000...3000 m with current derating 1 % per 100 m <= 1000 m without derating |
Driftsstilling | Vertical +/- 10 degree |
Dybde | 315 mm |
EAN-nummer | 3389119406109 |
EMC filter | Class C1 EMC filter integrated |
Faseantal | 3 faser |
Forsyningsspændingsgrænser | 323...528 V |
Forureningsgrad | 3 i henhold til UL 840 3 i henhold til EN/IEC 61800-5-1 |
Frekens | 8...16 kHz with derating factor 2...16 kHz Justerbar |
Electromagnetisk kompatibilitet | Voltage dips and interruptions immunity test i henhold til IEC 61000-4-11 Radiated radio-frequency electromagnetic field immunity test i henhold til IEC 61000-4-3 Level 3 Electrostatic discharge immunity test i henhold til IEC 61000-4-2 Level 3 Electrical |
Elektrisk tilslutning | L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB terminal 25 mm2 / AWG 3 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR terminal 2.5 mm2 / AWG 14 |
Forsyning | Internal supply 24 V DC (21...27 V), <= 200 mA til overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <= 10 mA til overload and short-circuit protection Ekstern forsyning 24 V DC (19...30 V) |
Fysisk interface | 2-wire RS 485 til Modbus |
Hastighedsområde | 1...100 in open-loop mode, without speed feedback |
Hyppig beslutning | Display enhed 0.1 Hz Analog indgang 0.024/50 Hz |
Højde | 665 mm |
IP kapslingsklasse | IP54 i henhold til UL Type 12 IP54 i henhold til EN/IEC 61800-5-1 IP54 i henhold til EN/IEC 60529 |
Isolationsmodstand | > 1 mOhmved 500 V DC for 1 minute to earth |
Klemmetype | Male SUB-D 9 on RJ45 til CANopen 1 RJ45 til Modbus på terminal 1 RJ45 til Modbus on front face |
Kommerciel status | Commercialised |
Lagerkode | Ikke på lager |
Ledningstype | Without mounting kit : 1-strand IEC cableved 45 °C, kobber 90 °C XLPE/EPR Without mounting kit : 1-strand IEC cableved 45 °C, kobber 70 °C PVC With UL Type 1 kit : 3-strand UL 508 cableved 40 °C, kobber 75 °C PVC With an IP21 or an IP31 kit : 3-strand IEC |
Linearitetsfejl | AO1 +/- 0.2 % AI2 +/- 0.15 % af maksimum værdi AI1-/Al1+ +/- 0.15 % af maksimum værdi |
Lokal indikering | 1 LED rød tilstedeværelse af drive voltage |
Maximum sluttestrøm | R1, R2 til modstandsdygtig belastning, 5 Aved 30 V DC, cos phi = 1, L/R = 0 ms R1, R2 til modstandsdygtig belastning, 5 Aved 250 V AC, cos phi = 1, L/R = 0 ms R1, R2 til inductiv belastning, 2 Aved 30 V DC, cos phi = 0.4, L/R = 7 ms R1, R2 til inductiv be |
Maximum transient current | 47.8 A til 60 s 3 faser |
Minimum sluttestrøm | Configurable relay logic 3 mAved 24 V DC |
Motor slip compensation | Justerbar Automatic whatever the load Can be suppressed Not available in voltage/frequency ratio (2 or 5 points) |
Motoreffekt i hp | 30 hp 3 faserved 380...480 V |
Motoreffekt i kW | 22 kW 3 faserved 380...480 V |
Mærkning | CE |
Netfrekvensgrænse | 47.5...63 Hz |
Nominal switching frequency | 4 kHz |
Option card | Profibus DP V1 kommunikationskort Profibus DP kommunikationskort Multi-pumpekort Modbus/Uni-Telway kommunikationskort Modbus TCP kommunikationskort Modbus Plus kommunikationskort METASYS N2 kommunikationskort LonWorks kommunikationskort Interbus-S kommuni |
Polaritetstype | Ingen impedance til Modbus |
Productcertificeringer | CSA C-Tick DNV GOST NOM 117 UL |
Produktsortiment | Altivar 61 |
Produktspecifik applikation | Pumping and ventilation machine |
Produkttype | Frekvensomformer |
Prospektiv kortslutningsstrøm Isc | 22 kA 3 faser |
Protokol for kommunikationsport | CANopen Modbus |
Reaktionstid | R2A, R2B <= 7 ms, tolerance +/- 0.5 ms R1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 ms <= 100 ms in STO (Safe Torque Off) |
Regulation loop | Frequency PI regulator |
Relativ fugtighed | 5...95 % without dripping water i henhold til IEC 60068-2-3 5...95 % without condensation i henhold til IEC 60068-2-3 |
Prøvevarighed | Separat indgang LI6 (if configured as logic input) 2 ms, +/- 0.5 ms Separat indgang LI1...LI5 2 ms, +/- 0.5 ms Analog udgang AO1 2 ms, +/- 0.5 ms Analog indgang Al2 2 ms, +/- 0.5 ms Analog indgang AI1-/Al1+ 2 ms, +/- 0.5 ms |
Sammenbygningens type | Enclosed |
Shockmodstand | 15 gn til 11 ms i henhold til EN/IEC 60068-2-27 |
Speed accuracy | +/- 10 % of nominal slip til 0.2 Tn to Tn vridningsvariation without speed feedback |
Speed drive output frequency | 0.1...1000 Hz |
Standarder | EN 55011 group 1 klasse B EN 61800-3 miljø 1 kategori C1 EN 61800-3 miljø 2 kategori C1 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3-3 class 3C1 IEC 60721-3-3 class 3S2 UL Type 12 |
Støjgrænse | 60.2 dB i henhold til 86/188/EEC |
Synkronmotorkontrol | Vector control without sensor, standard |
Tilgangs metode | Slave til CANopen |
Tilgangsstrøm | 43.6 A til 380 V 3 faser 22 kW / 30 hp 36.6 A til 480 V 3 faser 22 kW / 30 hp |
Tilslutningsfrekvens | 50...60 Hz (- 5...5 %) |
Tilspændingsmoment | L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB 5.4 N.m / 47.7 lb.in AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR 0.6 N.m |
Tilsyneladende effekt | 28.7 kVA til 380 V 3 faser 22 kW / 30 hp |
Torque accuracy | +/- 15 % in open-loop mode, without speed feedback |
Transient overmoment | 130 % of nominal motor torque, +/- 10 % til 60 s |
Transmissionsstel | RTU til Modbus |
Transmissionsstørrelse | 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps til CANopen 9600 bps, 19200 bps til Modbus on front face 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps til Modbus på terminal |
Type nr. | ATV61 |
Udgangsspænding | <= power supply voltage |
Vedvarende udgangsstrøm | 43.5 Aved 4 kHz, 380 V 3 faser 40 Aved 4 kHz, 460 V 3 faser |
Vibrationsmodstand | 1.5 mm peak to peak (f = 3...13 Hz) i henhold til EN/IEC 60068-2-6 1 gn (f = 13...200 Hz) i henhold til EN/IEC 60068-2-6 |
Vægt | 50 kg |