Navigér
Sœg

Pressostat FTG 4.6 bar - fast scale 1 threshold - 2NC


Varenr: FTG2NE
Produktet findes ikke i SAP!

[In] rated current10 A at 250 V AC conforming to EN 60730-1
[Ui] rated insulation voltage500 V conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
Adjustable range of switching point on falling pressure0.3...3.1 bar
Adjustable range of switching point on rising pressure1.4...4.6 bar
Ambient air temperature for operation0...45 °C
Ambient air temperature for storage-30...80 °C
Cable entry2 entries incorporating Pg 13.5 plastic cable gland, cable outer diameter: 9...13 mm conforming to NF C 68-300
Class of protection against electric shockClass I conforming to IEC 536
Contacts type and composition2 NC snap action
Controlled fluidSea water (0...70 °C) Fresh water (0...70 °C)
Depth106 mm
Destruction pressure20 bar
Electrical circuit typePower circuit
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 1...2 x 2 mm˛
Electrical durability40000 cycles at 10 cyc/mn
Enclosure materialPS
Fluid connection typeG 1/4 (female) conforming to ISO 228
Height115 mm
IP degree of protectionIP65 conforming to EN/IEC 60529
Local displayWithout
Materials in contact with fluidNitrile Nylon 6/6 Zinc plated steel
Maximum permissible accidental pressure8 bar
Maximum permissible pressure - per cycle5.75 bar
Mechanical durability400000 cycles
Motor power kW1.5 kW 2 hp AC 400 V 3 phases 1.5 kW 2 hp AC 400 V 1 phase 1.5 kW 2 hp AC 230 V 3 phases 1.1 kW 1.5 hp AC 230 V 1 phase 1.1 kW 1.5 hp AC 110 V 3 phases 0.75 kW 1 hp AC 110 V 1 phase
Natural differential at high setting1.5 bar
Natural differential at low setting1.1 bar
Natural differential at middle setting1.3 bar
Operating positionAny position
Operating rate10 cyc/mn
Pressure actuatorDiaphragm
Pressure sensor nameFTG
Pressure sensor size4.6 bar
Pressure sensor typeElectromechanical pressure sensor
Pressure switch type of operationDetection of single threshold
Product specific application-
Product weight0.34 kg
Protective treatmentTC
Range of productOsiSense XM
Repeat accuracy< 2 %
Scale typeFixed differential
SettingInternal
Short circuit protection20 A cartridge fuse type gG
StandardsCE EN/IEC 60730
Terminal block type4 terminals
Terminals description ISO n°1(1-2)NC (3-4)NC
Width72 mm

Yderliger oplysninger: Se venligst SE katalog









©Schneider Electric A/S 2025

Katalog

Hjem Info