TeSys D kontaktor 4 poler(4 NO) AC-1 <= 440 V 40 A - 42 V AC


Varenr:LC1DT40D7
El nr:7522457985
EAN13 nr:3389110673722
Pakning:1stk

[Icw] rated short-time withstand current140 A 100 ms signalling circuit 120 A 500 ms signalling circuit 100 A 1 s signalling circuit 380 A <= 40 °C 1 s power circuit 240 A <= 40 °C 10 s power circuit 120 A <= 40 °C 1 min power circuit 50 A <= 40 °C 10 min power circuit
[Ie] rated operational current40 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
[Ith] conventional free air thermal current40 A at <= 60 °C for power circuit 10 A at <= 60 °C for signalling circuit
[Ue] rated operational voltage<= 300 V DC for power circuit <= 690 V AC 25...400 Hz for power circuit
[Ui] rated insulation voltage690 V for power circuit conforming to IEC 60947-4-1 600 V for signalling circuit certifications UL 600 V for signalling circuit certifications CSA 690 V for signalling circuit conforming to IEC 60947-1 600 V for power circuit certifications UL 600 V for p
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Ambient air temperature for operation-5...60 °C
Ambient air temperature for storage-60...80 °C
Associated fuse rating40 A gG at <= 690 V coordination type 2 for power circuit 63 A gG at <= 690 V coordination type 1 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typeType mirror contact (1 NC) conforming to IEC 60947-4-1 Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Average impedance2 mOhm at 50 Hz - Ith 40 A for power circuit
Coil technologyWithout built-in suppressor module
Connections - terminalsPower circuit : connector 2 cable(s) 2.5...16 mm² - cable stiffness: solid - without cable end Power circuit : connector 1 cable(s) 2.5...16 mm² - cable stiffness: solid - without cable end Power circuit : connector 2 cable(s) 2.5...10 mm² - cable stiffne
Contactor applicationResistive load
Control circuit typeAC 50/60 Hz
Control circuit voltage42 V AC 50/60 Hz
Control circuit voltage limits0.85...1.1 Uc at 60 °C operational 60 Hz 0.8...1.1 Uc at 60 °C operational 50 Hz 0.3...0.6 Uc at 60 °C drop-out 50/60 Hz
Depth99 mm
Device short nameLC1D
Electrical durability1.4 Mcycles 40 A AC-1 at Ue <= 440 V
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Heat dissipation2...3 W at 50/60 Hz
Height91 mm
Hold-in power consumption in VA7 VA at 20 °C (cos ? 0.3) 50 Hz 7.5 VA at 20 °C (cos ? 0.3) 60 Hz
Inrush power in VA70 VA at 20 °C (cos ? 0.75) 50 Hz 70 VA at 20 °C (cos ? 0.75) 60 Hz
Insulation resistance> 10 MOhm for signalling circuit
IP degree of protectionIP2x front face conforming to IEC 60529
Mechanical durability15 Mcycles
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Irms rated making capacity450 A at 440 V for power circuit conforming to IEC 60947 250 A DC for signalling circuit conforming to IEC 60947-5-1 140 A AC for signalling circuit conforming to IEC 60947-5-1
Mechanical robustnessShocks contactor open 8 Gn for 11 ms Shocks contactor closed 15 Gn for 11 ms Vibrations contactor closed 4 Gn, 5...300 Hz Vibrations contactor open 2 Gn, 5...300 Hz
Mounting supportPlate Rail
Non-overlap time1.5 ms on energisation (between NC and NO contact) 1.5 ms on de-energisation (between NC and NO contact)
Operating altitude3000 m without derating in temperature
Operating rate3600 cyc/h at <= 60 °C
Operating time12...22 ms closing 4...19 ms opening
Overvoltage categoryIII
Permissible ambient air temperature around the device-40...70 °C at Uc
Poles description4P
Pollution degree3
Power dissipation per pole3.2 W AC-1
Power pole contact composition4 NO
Product certificationsBV CCC CSA DNV GL GOST RINA UL LROS
Product end of life instructionsNeed no specific recycling operations
Product environmental profileAvailable
Product nameTeSys D
Product or component typeContactor
Product weight0.425 kg
Protective treatmentTH conforming to IEC 60068-2-30
RangeTeSys
Rated breaking capacity450 A at 440 V for power circuit conforming to IEC 60947
REAChReference not containing SVHC above the threshold
RoHSCompliant - since 0702 -  Schneider Electric declaration of conformity
Safety coverWith
Safety reliability levelB10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Signalling circuit frequency25...400 Hz
StandardsEN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14
Sustainable offer statusGreen Premium product
Tightening torquePower circuit : 1.7 N.m - on connector - with screwdriver Philips No 2 Power circuit : 1.7 N.m - on connector - with screwdriver flat Ø 6 mm Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit : 1.7 N.m - o
Utilisation categoryAC-1
Width45 mm