TeSys LK-motorstarter med reversering AS-interface - 0.09 KW - drejehåndtag


Varenr:LF4P05D
El nr:7522513476
EAN13 nr:3389118325241
Pakning:1stk

[Ith] conventional free air thermal current5 A for output control relay
[Uc] control circuit voltage24 V DC
[Ue] rated operational voltage415 V
[Ui] rated insulation voltage1500 V AC 50/60 Hz 60 s between output and earth or between output and internal logic
AS-interface profile7.D.F.F standard addressing 7.A.7.0 extended adressing A/B
Contactor applicationMotor control
Control circuit voltage limits250 V for AC circuit output control relay 30 V for DC circuit
Control typeRotary knob blue Rotary knob black
Depth175 mm
Device short nameLF4P
Electrical durability800000 cycles automatic operation 100000 cycles manual operation
Enclosure materialPolycarbonate impregnated glass fiber
Breaking capacityIcu > 100 kA at 400...415 V conforming to IEC 60947-2 Icu > 100 kA at 230...240 V conforming to IEC 60947-2 Ics > 100 kA at 400...415 V conforming to IEC 60947-2 Ics > 100 kA at 230...240 V conforming to IEC 60947-2
Connections - terminalsPower supply: screw clamp terminals 2 cable <= 6 mm² - cable stiffness: solid Power supply: screw clamp terminals 2 cable <= 6 mm² - cable stiffness: flexible - without cable end Power supply: screw clamp terminals 2 cable <= 4 mm² - cable stiffness: flex
Current consumption30 mA at 24 V DC for auxiliary supply energisation 20 mA for AS-Interface line sealed 20 mA for AS-Interface line relays 20 mA for AS-Interface line inrush 20 mA for AS-Interface line de-energisation 110 mA at 24 V DC for auxiliary supply inrush 0 mA at 2
Fire resistance960 °C conforming to IEC 60695-2-1
Height195 mm
Input current> 6 mA state 1 > 2 mA state 0
Input descriptionStatus D3 (0) sensor 2 Status D2 (0) sensor 1 Status D1 (0) running Status D0 (0) ready
Input voltage> 11 V DC state 1 < 5 V DC state 0
IP degree of protectionIP54 conforming to IEC 60529
Maximum sensor supply current50 mA
Mechanical durability5000000 cycles automatic operation 100000 cycles manual operation
Motor power kW0.25 kW at 400...415 V AC 50/60 Hz 0.12 kW at 220...230 V AC 50/60 Hz 0.09 kW at 220...230 V AC 50/60 Hz
Motor starter compositionContactor With circuit breaker
Motor starter typeReversing
Network frequency50/60 Hz
Network typeAC
Non-dissipating shock wave2.5 kV AS-Interface conforming to IEC 60947-1 2.5 kV 1 line/standard for sensor conforming to IEC 60947-1 2.5 kV 1 line/standard for 24 V conforming to IEC 60947-1 6 kV power conforming to IEC 60947-1
Number of sensors2
Operating altitude<= 2000 m
Output descriptionCommand D3 (O) not used - bit value: bit value 1 Command D2 (O) control relay - bit value: bit value 1 Command D1 (O) reverse running - bit value: bit value 1 Command D0 (O) forward running - bit value: bit value 1
Poles description3P
Product end of life instructionsNeed no specific recycling operations
Product or component typeEnclosed DOL starter
Product weight1.55 kg
Protection typeOverload protection a quick-blow fuse must be fitted DC inductive overloads by switching the coils of preactuators Against short-circuits a quick-blow fuse must be fitted AC inductive overloads by switching the coils of preactuators
Protective treatmentTC
Range of productTeSys
Resistance across terminals> 1000 mOhm between output terminals and AS-Interface
Resistance to electrostatic discharge8 kV open air conforming to IEC 61000-4-2 8 kV open air conforming to EN 61000-4-2 4 kV indirect mode conforming to IEC 61000-4-2 4 kV indirect mode conforming to EN 61000-4-2
Resistance to fast transients2 kV power conforming to IEC 61000-4-4 2 kV power conforming to EN 61000-4-4 2 kV AS-Interface conforming to IEC 61000-4-4 2 kV AS-Interface conforming to EN 61000-4-4 2 kV 24 V sensor conforming to IEC 61000-4-4 2 kV 24 V sensor conforming to EN 61000-4-
Response time< 15 ms unlatching for output control relay < 10 ms latching for output control relay
RoHSCompliant - since 0925 -  Schneider Electric declaration of conformity
Shock resistance15 gn contactor closed conforming to IEC 60068-2-27 10 gn contactor open conforming to IEC 60068-2-27
StandardsEN 60204-1 EN 60947-1 IEC 60439-1
Sustainable offer statusNot Green Premium product
Resistance to radiated fields10 V/m immunity tests-radiated disturbances conforming to ENV 50204 10 V/m immunity tests-radiated disturbances conforming to ENV 50141 10 V/m immunity tests-radiated disturbances conforming to ENV 50140 10 V/m immunity tests-conducted disturbances confor
Service life in cycles5000000 cycles at 0.25 A 24 V AC AC-14 - load type inductive - for output control relay 1000000 cycles at 0.5 A 24 V AC AC-14 - load type inductive - for output control relay > 1000000 cycles at 0.25 A 24 V DC DC-3 - load type resistive - for output contr
Thermal protection adjustment range0.63...1 A
Tightening torquePower supply: 1.7 N.m - with screwdriver Philips No 2 Power supply: 1.7 N.m - with screwdriver flat Ø 5.5 mm Output control relay: 0.7 N.m - with screwdriver flat Ø 3.5 mm Motor: 0.8 N.m - with screwdriver Philips No 2 Motor: 0.8 N.m - with screwdriver fl
Trip unit technologyThermal-magnetic
Utilisation categoryAC-3
Vibration resistance4 gn 5...150 Hz contactor closed conforming to IEC 60068-2-6 2 gn 5...150 Hz contactor open conforming to IEC 60068-2-6
Width175 mm
Wiring technique2-wire 3-wire

Yderliger oplysninger: Se venligst SE katalog