[Ics] rated service breaking capacity | 50 kA 440 V 50 kA 230 V 4 kA 690 V 10 kA 500 V |
[Ie] rated operational current | 9 A på 690 V 12 A på 500 V 12 A på <= 440 V |
[Ith] conventional free air thermal current | 12 A |
[Ue] rated operational voltage | 690 V 500 V 440 V 230 V |
[Ui] rated insulation voltage | 600 V i henhold til CSA C22.2 No 14 690 V i henhold til IEC 60947-1 3 600 V i henhold til UL 508 |
[Uimp] rated impulse withstand voltage | 6 kV i henhold til IEC 60947-6-2 |
Ambient air temperature for operation | -25...70 °C with LUCA, LUCB, LUCC, LUCD -25...60 °C with LUCM |
Ambient air temperature for storage | -40...85 °C |
Arbejdsforhold | 60 cyc/mn |
Auxiliary contact composition | 2 NO |
Beskyttelsesbehandling | TH i henhold til IEC 60068 |
Brandmodstand | 650 °C i henhold til IEC 60695-2-12 960 °C parts supporting live components i henhold til IEC 60695-2-12 |
Bredde | 45 mm |
Driftshøjde | 2000 m |
Driftstid | 70 ms closing with LUCA, LUCB, LUCC, LUCD til control circuit 75 ms closing with LUCM til control circuit 35 ms åben with LUCA, LUCB, LUCC, LUCD, LUCM til control circuit 75 ms without change of direction til effekt kreds 150 ms with change of direction t |
Duration of inrush phase | 15 ms til DC netværk |
Dybde | 126 mm |
EAN-nummer | 3389110363098 |
Egnet for adskillelse | Ja |
Enhedens korte navn | LU2B |
Hjælpekontakttype | Type intern kontakt (1 NC) state of the power i henhold til draft IEC 60947-1 Type linked contacts (1 NO + 1 NC) i henhold til IEC 60947-4-1 |
Højde | 224 mm |
Ikke-sprdende shockbølge | 0 kV 24 V DC 2 kV fælles mode 24...240 V AC i henhold til IEC 60947-6-2 1 kV serial mode 48...220 V DC i henhold til IEC 60947-6-2 |
Immunitet overfor elektriske felter | 10 V i henhold til IEC 61000-4-6 |
Immunitet til spændingsdyk | 70 % 500 ms i henhold til IEC 61000-4-11 |
Imunitet over for microafbrydelser | 3 ms |
IP kapslingsklasse | 22-26 front panel outside connection zone i henhold til IEC 60947-1 18-22 other faces i henhold til IEC 60947-1 18-22 front panel and wired terminals i henhold til IEC 60947-1 |
Kommerciel status | Commercialised |
Lagerkode | Ikke på lager |
Mekanisk holdbarhed | 15000000 kredsløb |
Modstand mod hurtige transienter | 4 kV klasse 4 all circuits except for serial link i henhold til IEC 61000-4-4 2 kV klasse 3 seriel link i henhold til IEC 61000-4-4 |
Modstand mod udstrålede felter | 10 V/m 3 i henhold til IEC 61000-4-3 |
Netfrekvens | 40...60 Hz |
Polbeskrivelse | 3P |
Product name | TeSys U |
Productcertificeringer | ABS ASEFA ATEX BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) UL |
Produkttype | Reversing power base |
Range | TeSys |
Resistance to electrostatic discharge | 8 kV niveaul 4 on contact i henhold til IEC 61000-4-2 8 kV niveaul 3 in open air i henhold til IEC 61000-4-2 |
Safety reliability level | B10d 20000000 kredsløb contactor with mechanical load passer til EN/ISO 13849-1 B10d 1369863 kredsløb contactor with nominal load passer til EN/ISO 13849-1 |
Shockmodstand | 15 gn power poles closed i henhold til IEC 60068-2-27 10 gn power poles open i henhold til IEC 60068-2-27 |
Sikkerhedsadskillelse af kredse | 400 V SELV between the control or auxiliary circuit and the main circuit i henhold til IEC 60947-1 appendix N 400 V SELV between the control and auxiliary circuits i henhold til IEC 60947-1 appendix N |
Standarder | CSA C22.2 No 14 type E IEC 60947-6-2 EN 60947-6-2 UL 508 Type E with phase barrier |
Strømvarmetab | 1.7 W til control circuit with LUCM 2 W til control circuit with LUCA, LUCB, LUCC, LUCD |
Styrekredsens spændingsgrænser | 20...27 V 24 V DC in operation 14.5 V 24 V DC drop-out |
Styrespænding | 24 V DC |
Tilslutningsklemmer | Control circuit : without connection Effekt kreds : skrue klemmeterminaler 2 kabel 1.5...6 mm² - kabel stivhed: fleksibel - uden kabelende Effekt kreds : skrue klemmeterminaler 2 kabel 1...6 mm² - kabel stivhed: stiv - uden kabelende Effekt kreds : skrue |
Typical current consumption | 70 mA I rms sealed with LUCM 60 mA I rms sealed with LUCA, LUCB, LUCC, LUCD 150 mA I maximum while closing with LUCM 130 mA I maximum while closing with LUCA, LUCB, LUCC, LUCD |
Utilisation category | AC-41 AC-43 AC-44 |
Vibrationsmodstand | 4 gn 5...300 Hz power poles closed i henhold til IEC 60068-2-27 2 gn 5...300 Hz power poles open i henhold til IEC 60068-2-27 |
Vægt | 1.27 kg |