 |
[Ui] rated insulation voltage | 600 V i henhold til CSA C22.2 No 14 690 V i henhold til IEC 60947-1 600 V i henhold til UL 508 |
[Uimp] rated impulse withstand voltage | 6 kV i henhold til IEC 60947-6-2 |
Ambient air temperature for operation | -25...70 °C |
Ambient air temperature for storage | -40...85 °C |
Belastningstype | 3-faset motor - afkøling: self-cooled |
Beskyttelsesbehandling | TH i henhold til IEC 60068 |
Brandmodstand | 650 °C i henhold til IEC 60695-2-12 960 °C parts supporting live components i henhold til IEC 60695-2-12 |
Driftshøjde | 2000 m |
Driftstid | 70 ms closing with LUB32 til control circuit 70 ms closing with LUB12 til control circuit 35 ms åben with LUB32 til control circuit 35 ms åben with LUB12 til control circuit |
EAN-nummer | 3389110364828 |
Enhedens korte navn | LUCD |
Function available | Jord fejlbeskyttet Manuel reset Protection against overload and short-circuit Protection against phase failure and phase imbalance |
Grænseværdi for udløsning | 14.2 x Ir +/- 20 % |
Immunitet overfor elektriske felter | 10 V i henhold til IEC 61000-4-6 |
Immunitet til spændingsdyk | 70 % 500 ms i henhold til IEC 61000-4-11 |
Imunitet over for microafbrydelser | 3 ms |
Indstillingsområde for termsik beskyttelse | 3...12 A |
IP kapslingsklasse | 22-26 front panel outside connection zone i henhold til IEC 60947-1 18-22 other faces i henhold til IEC 60947-1 18-22 front panel and wired terminals i henhold til IEC 60947-1 |
Kommerciel status | Commercialised |
Kompatibilitet | ASILUFC5 ASILUFC51 LUFC00 LUFDA01 LUFDA10 LUFDH11 LUFN.. LUFV2 LUFW10 LULC031 LULC033 LULC07 LULC08 LULC09 LULC15 |
Lagerkode | På lager |
Modstand mod hurtige transienter | 4 kV klasse 4 all circuits except for serial link i henhold til IEC 61000-4-4 2 kV klasse 3 seriel link i henhold til IEC 61000-4-4 |
Modstand mod udstrålede felter | 10 V/m 3 i henhold til IEC 61000-4-3 |
Montage | Plug-in |
Montagested | Front side |
Motoreffekt i kW | 5.5 kW på 500 V AC 50/60 Hz 5.5 kW på 400...440 V AC 50/60 Hz 9 kW på 690 V AC 50/60 Hz |
Product end of life instructions | Available Download Bortskaffelsesmanual |
Product environmental profile | Tilgængelig Download Produktmiljøprofil |
Product name | TeSys U |
Productcertificeringer | ABS ASEFA ATEX BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) UL |
Produktspecifik applikation | Basic protection and advanced functions, communication |
Produkttype | Avanceret kontrol enhed |
Overbelastningsudløsningsklasse | Klasse 20 - frekvensbegrænsning: 40...60 Hz - temperaturkompensation: -25...70 °C - passer til UL 508 Klasse 20 - frekvensbegrænsning: 40...60 Hz - temperaturkompensation: -25...70 °C - passer til IEC 60947-6-2 |
Range | TeSys |
REACh | Reference not containing SVHC above the threshold |
Resistance to electrostatic discharge | 8 kV niveaul 4 on contact i henhold til IEC 61000-4-2 8 kV niveaul 3 in open air i henhold til IEC 61000-4-2 |
RoHS (date code: YYWW) | Compliant - since 1015 - Schneider Electric declaration of conformity |
Shockmodstand | 15 gn power poles closed i henhold til IEC 60068-2-27 10 gn power poles open i henhold til IEC 60068-2-27 |
Sikkerhedsadskillelse af kredse | 400 V SELV between the control or auxiliary circuit and the main circuit i henhold til IEC 60947-1 400 V SELV between the control and auxiliary circuits i henhold til IEC 60947-1 |
Standarder | CSA C22.2 No 14 type E IEC 60947-6-2 EN 60947-6-2 UL 508 Type E with phase barrier |
Strømvarmetab | 3 W til control circuit with LUB32 2 W til control circuit with LUB12 |
Styrekredsens spændingsgrænser | 20...27 V til DC kredsløb 24 V in operation |
Styrespænding | 24 V DC |
Sustainable offer status | Green Premium produkt |
Typical current consumption | 80 mA på 24 V DC I rms sealed with LUB32 60 mA på 24 V DC I rms sealed with LUB12 220 mA på 24 V DC I maximum while closing with LUB32 130 mA på 24 V DC I maximum while closing with LUB12 |
Utilisation category | AC-41 AC-43 AC-44 |
Vibrationsmodstand | 4 gn 5...300 Hz power poles closed i henhold til IEC 60068-2-6 2 gn 5...300 Hz power poles open i henhold til IEC 60068-2-6 |