TM241 PLC, Eth,DI14,DO 10PNP 24V


Varenr:TM241CE24T
El nr:7586048039
EAN13 nr:3606480611193
Pakning:1stk

[Us] rated supply voltage24 V DC
Accuracy+/- 1 % at 100 Hz...1 kHz for fast output +/- 0.1 % at 20...100 Hz for fast output
Ambient air temperature for operation-10...55 °C for horizontal installation -10...50 °C for vertical installation
Ambient air temperature for storage-25...70 °C
Application structure8 event tasks 4 cyclic master tasks 3 cyclic master tasks + 1 freewheeling task 8 external event tasks
Backup time2 years at 25 °C
Battery typeBR2032 lithium non-rechargeable, battery life: 4 yr
Cable length<= 3 m shielded cable for fast output <= 50 m unshielded cable for output <= 10 m shielded cable for fast input <= 50 m unshielded cable for input
Clock drift<= 60 s/month at 25 °C
Communication port protocolModbus non isolated serial link with master/slave method
Configurable filtering time12 ms for input 4 ms for input 1 ms for input 0 ms for input 12 ms for fast input 1 µs for fast input
Control signal typeSingle phase signal at 200 kHz for fast input (HSC mode) Pulse/direction signal at 200 kHz for fast input (HSC mode) A/B signal at 100 kHz for fast input (HSC mode)
Counting input number4 fast input (HSC mode)
Current per output common1 A with Q8...Q9 terminal for output 2 A with Q4...Q7 terminal for output 2 A with Q0...Q3 terminal for fast output
Current state 0 guaranteed<= 1.5 mA for fast input <= 1 mA for input
Current state 1 guaranteed>= 5 mA for fast input >= 2.5 mA for input
Data backed up128 MB built-in flash memory for backup of user programs
Data storage equipment<= 32 GB SD card optional
Depth95 mm
Discrete I/O number24
Discrete input current10.7 mA for fast input 5 mA for input
Discrete input logicSink or source
Discrete input number14 discrete input including 8 fast input conforming to IEC 61131-2 Type 1
Discrete input voltage24 V
Discrete input voltage typeDC
Discrete output current0.1 A with Q0...Q3 terminal(s) for fast output (PTO mode) 0.5 A with Q0...Q9 terminal(s) for transistor output
Discrete output logicPositive logic (source)
Discrete output number10 transistor including 4 fast output
Discrete output typeTransistor
Discrete output voltage24 V DC for transistor output
Electrical connectionRemovable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm) Removable screw terminal block for inputs and outputs (pitch 5.08 mm)
Electromagnetic emissionRadiated emissions, test level: 47 dB?V/m QP with class A (radio frequency: 230 MHz...1 GHz) conforming to EN/IEC 55011 Radiated emissions, test level: 40 dB?V/m QP with class A (radio frequency: 30...230 MHz) conforming to EN/IEC 55011 Conducted emission
Ethernet servicesFTP server SNMP DHCP client Ethernet/IP adapter Modbus TCP server Modbus TCP client IEC VAR ACCESS Modbus TCP slave device
Execution time for 1 KInstruction0.7 ms for other instruction 0.3 ms for event and periodic task
Height90 mm
Immunity to microbreaks10 ms
Input impedance2.81 kOhm for fast input 4.7 kOhm for input
Inrush current<= 50 A
Insulation500 V AC between output groups 500 V AC between fast output and internal logic Non-insulated between outputs 500 V AC between output and internal logic 500 V AC between fast input and internal logic Non-insulated between inputs 500 V AC between input and
Integrated connection typeEthernet with connector RJ45 USB port with connector mini B USB 2.0 Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485 Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485
IP degree of protectionIP20 with protective cover in place
Leakage current<= 5 µA for output
Local signalling1 LED green for Ethernet port activity 1 LED per channel green for I/O state 1 LED red for bus fault on TM4 (TM4) 1 LED green for SL2 1 LED green for SL1 1 LED red for BAT 1 LED green for SD card access (SD) 1 LED red for I/O error (I/O) 1 LED red for mod
MarkingCE
Maximum number of connections8 connection(s) for Modbus server 16 connection(s) for Ethernet/IP device
Memory capacity64 MB for system memory RAM 8 MB for program
Mounting supportPlate or panel with fixing kit Top hat type TH35-7.5 rail conforming to IEC 60715 Top hat type TH35-15 rail conforming to IEC 60715
Number of I/O expansion module14 (remote I/O architecture) 7 (local I/O architecture)
Operating altitude0...2000 m
Output frequency<= 1 kHz for output <= 100 kHz for fast output (PLS mode) <= 20 kHz for fast output (PWM mode)
Output voltage limits30 V DC
Pollution degree2
Port Ethernet1 - 10BASE-T/100BASE-TX port with copper cable support
Positioning functionsPWM/PTO function 4 channel(s) (positioning frequency: 100 kHz)
Power consumption in W32.6...40.4 W
Product certificationsCSA CULus IACS E10 RCM
Product end of life instructionsAvailable Download End of life manual
Product environmental profileAvailable Download Product environmental
Product or component typeLogic controller
Product weight0.53 kg
Protection typeReverse polarity protection for fast output Short-circuit and overload protection with automatic reset Short-circuit protection
Range of productModicon M241
REAChReference not containing SVHC above the threshold
Realtime clockWith
Relative humidity10...95 % without condensation in storage 10...95 % without condensation in operation
Reset time12 s fast output 10 ms output
Resistance to conducted disturbances, induced by radio frequency fields10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) 3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
Resistance to electromagnetic fields1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
Resistance to electrostatic discharge4 kV on contact conforming to EN/IEC 61000-4-2 8 kV in air conforming to EN/IEC 61000-4-2
Resistance to fast transients1 kV for transistor output conforming to EN/IEC 61000-4-4 1 kV for input conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for Ethernet line conforming to EN/IEC 61000-4-4 2 kV for power lines conforming to EN/IEC 610
Response time<= 2 µs turn-off operation with Q0...Q3 terminal(s) for fast output <= 2 µs turn-on operation with Q0...Q3 terminal(s) for fast output <= 250 µs turn-off operation with Q0...Q9 terminal(s) for output <= 34 µs turn-on operation with Q0...Q9 terminal(s) for
RoHS (date code: YYWW)Compliant - since 1330 -  Schneider Electric declaration of conformity
Shock resistance15 gn for 11 ms
StandardsCSA C22.2 No 142 UL 1604 UL 508 ANSI/ISA 12-12-01 CSA C22.2 No 213 EN/IEC 61131-2 : 2007 Marine specification (LR, ABS, DNV, GL)
Storage altitude0...3000 m
SupplySerial link supply "serial 1" at 5 V, 200 mA
Supply voltage limits20.4...28.8 V
Surge withstand1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5 1 kV for input in common mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in differential mod
Sustainable offer statusGreen Premium product
Tungsten load<= 2.4 W
Voltage drop<= 1 V
Voltage state 0 guaranteed<= 5 V for input
Voltage state1 guaranteed>= 15 V for input
Web servicesWeb server
Width150 mm
Transmission rate10/100 Mbit/s - communication protocol: Ethernet 480 Mbit/s for bus length of 3 m - communication protocol: USB 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 1.2...115.2 kbit/s (115.2 kbit/s by default)
Vibration resistance3 gn (vibration frequency: 8.4...150 Hz) on panel mounting 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail