Endestop med reset kort arm med rulle


Varenr:XCDR2519P20
El nr:7524715036
EAN13 nr:3389110212419
Pakning:1stk

[Ui] rated insulation voltage300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to IEC 60947-1 500 V degree of pollution 3 conforming to EN 60947-1 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Body materialZamak
Body typeFixed
Cable entry1 entry tapped for M20 x 1.5 cable gland, cable outer diameter: 7...13 mm
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to IEC 61140
Contact code designationQ300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
Contacts insulation formZb
Contacts operationSlow-break, break before make
Contacts type and composition1 NC + 1 NO
Depth30 mm
Device short nameXCDR
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Fixing modeBy the body
Head materialZamak
Head typeRotary head
Height65 mm
IK degree of protectionIK04 conforming to EN 50102
IP degree of protectionIP67 conforming to IEC 60529 IP66 conforming to IEC 60529
MaterialMetal
Maximum actuation speed1.5 m/s
Minimum torque for tripping0.1 N.m
Movement of operating headRotary
Electrical durability5000000 cycles DC-13 48 V 7 W <= 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles DC-13 24 V 10 W <= 60 cyc/mn 0.5 IEC 60947-5-1 appendix C 5000000 cycles DC-13 120 V 4 W <= 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Number of poles2
Positive openingWith
Positive opening minimum torque0.25 N.m
Product certificationsCSA UL
Product end of life instructionsNeed no specific recycling operations
Product environmental profileAvailable Download Product environmental
Product or component typeLimit switch
Product weight0.255 kg
Protective treatmentTC
Range of productOsiSense XC
REAChReference not containing SVHC above the threshold
Repeat accuracy0.1 mm on the tripping points with 1 million operating cycles
ResetWith
Resistance across terminals<= 25 MOhm conforming to IEC 60255-7 category 3
RoHS (date code: YYWW)Compliant - since 1103 -  Schneider Electric declaration of conformity
Sensor designCompact
Series nameStandard format
Shock resistance50 gn (duration = 11 ms) conforming to IEC 60068-2-27
Short circuit protection10 A by gG cartridge fuse
StandardsEN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14
Sustainable offer statusGreen Premium product
Switch actuationBy 30° cam
Terminals description ISO n°1(13-14)NO (21-22)NC
Tracks24/40 mm
Type of approachLateral approach 2 directions
Type of operatorSpring return roller lever metal
Vibration resistance25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Width31 mm