Navigér
Sœg

Endestop metal kort arm/rulle NO+NC


Varenr:XCKD2127P16
El nr:7524700106
EAN13 nr:3389110196900
Pakning:1stk

[Ui] rated insulation voltage300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to IEC 60947-1 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Body materialZamak
Body typeFixed
Cable entry1 entry tapped for M16 x 1.5 cable gland, cable outer diameter: 4...8 mm
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to IEC 61140
Contact code designationQ300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN 60947-5-1 A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V,
Contacts insulation formZb
Contacts operationSnap action
Contacts type and composition1 NC + 1 NO
Depth30 mm
Device short nameXCKD
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Electrical durability5000000 cycles, DC-13, 48 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 10 W, operating rate: <= 60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C 500000
Fixing modeBy the body
Head materialZamak
Head typePlunger head
Height65 mm
IK degree of protectionIK06 conforming to EN 50102
MaterialMetal
Maximum actuation speed1 m/s
Mechanical durability15000000 cycles
Minimum force for tripping6 N
Movement of operating headLinear
Number of poles2
Positive openingWith
Positive opening minimum force18 N
Product certificationsCCC CSA UL
Product end of life instructionsNeed no specific recycling operations
Product environmental profileAvailable Download Product environmental
Product or component typeLimit switch
Product weight0.19 kg
Protective treatmentTC
Range of productOsiSense XC
REAChReference not containing SVHC above the threshold
Repeat accuracy0.1 mm on the tripping points with 1 million operating cycles
Resistance across terminals<= 25 MOhm conforming to IEC 60255-7 category 3
RoHS (date code: YYWW)Compliant - since 1002 -  Schneider Electric declaration of conformity
Sensor designCompact
Series nameStandard format
Shock resistance50 gn (duration = 11 ms) conforming to IEC 60068-2-27
Short circuit protection10 A cartridge fuse gG
StandardsEN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14
Sustainable offer statusGreen Premium product
Switch actuationBy 30° cam
Terminals description ISO n°1(13-14)NO (21-22)NC
Type of approachVertical approach 1 direction
Type of operatorSpring return roller lever plunger thermoplastic
Vibration resistance25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Width31 mm

Yderliger oplysninger: Se venligst SE katalog









©Schneider Electric A/S 2025

Katalog

Hjem Info