Navigér
Sœg

Endestop metal stempel/rulle M18 snap 2N


Varenr:XCKD39H2P16EX
El nr:7524020585
EAN13 nr:3389118027626
Pakning:1stk

[Ithe] conventional enclosed thermal current6 A AC
[Ui] rated insulation voltage300 V conforming to CSA C22.2 No 14 400 V, pollution degree: 3 conforming to IEC 60947-1 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage4 kV conforming to IEC 60947-1 4 kV conforming to IEC 60664
Ambient air temperature for operation-20...60 °C
Body materialZamak
Body typeFixed
Cable entry number1 tapped entry (M16 x 1.5) for cable gland (included), cable outer diameter: 4...8 mm
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to IEC 61140
Contact code designationR300, DC-13 (250 V, Ie = 0.1 A) conforming to IEC 60947-5-1 appendix A R300, DC-13 (250 V, Ie = 0.1 A) conforming to EN 60947-5-1 B300, AC-15 (240 V, Ie = 1.5 A) conforming to IEC 60947-5-1 appendix A B300, AC-15 (240 V, Ie = 1.5 A) conforming to EN 60947
Contacts insulation formZb
Contacts operationSnap action
Contacts type and composition2 NC + 1 NO
Depth30 mm
Device short nameXCKD
Dust zoneZone 21 - 22
Electrical connectionScrew-clamp terminals, 1 x 0.34...2 x 0.75 mm²
Fixing modeBy the head
Head materialZamak
Head typeM18 plunger head
Height65 mm
IP degree of protectionIP67 conforming to IEC 60529 IP66 conforming to IEC 60529
Electrical durability5000000 cycles DC-13 48 V 3 W, <= 3600 cyc/mn load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive DC 5000000 cycles DC-13 24 V 4 W, <= 3600 cyc/mn load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive DC 5000000 cycles DC-13 120
MarkingII2 D-Ex tb IIIC T85°C Db IP66/67
MaterialMetal
Maximum actuation speed0.5 m/s
Mechanical durability10000000 cycles
Minimum actuation speed0.01 m/min
Minimum force for tripping10 N
Movement of operating headLinear
Number of poles3
Number of steps1
Positive openingWith
Positive opening minimum force36 N
Product certificationsINERIS 04ATEX0014X
Product end of life instructionsNeed no specific recycling operations
Product environmental profileAvailable Download Product environmental
Product or component typeLimit switch
Protective treatmentTC
Range of productOsiSense ATEX D
REAChReference not containing SVHC above the threshold
Resistance across terminals<= 25 MOhm conforming to IEC 60255-7 category 3
RoHSWill be Compliant on 4Q2012
Sensor designCompact
Series nameStandard format
Shock resistance50 gn for 11 ms conforming to IEC 60068-2-27
Short circuit protection6 A cartridge fuse, type gG
StandardsDirective ATEX 94/9/EC EN/IEC 60079-0 EN/IEC 60079-31
Sustainable offer statusNot Green Premium product
Switch actuationBy 30° cam
Type of approachLateral approach, 2 directions
Type of operatorSteel spring return roller plunger
Vibration resistance25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Width31 mm

Yderliger oplysninger: Se venligst SE katalog









©Schneider Electric A/S 2025