Navigér
Sœg

Endestop XCKJ - steel med stempel og rul - 1NC+1NO - slow-break - 1/2NPT


Varenr: XCKJ562H7
Produktet findes ikke i SAP!

[Ie] rated operational current0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current10 A
[Ui] rated insulation voltage300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to IEC 60947-1 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Body materialZamak
Body typeFixed
Cable entry1 entry tapped for 1/2" NPT cable gland
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to IEC 61140
Contacts insulation formZb
Contacts operationSlow-break, break before make
Contacts type and composition1 NC + 1 NO
Depth44 mm
Device short nameXCKJ
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Fixing modeBy the body
Head materialZamak
Head typePlunger head
Height77 mm
IK degree of protectionIK07 conforming to EN 50102
Electrical durability5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming
IP degree of protectionIP66 conforming to IEC 60529
MaterialMetal
Maximum actuation speed1 m/s
Minimum actuation speed6 m/min
Movement of operating headLinear
Number of poles2
Number of steps1
Positive openingWith
Positive opening minimum torque0.5 N.m
Product certificationsCCC CSA UL
Product end of life instructionsNeed no specific recycling operations
Product environmental profileAvailable Download Product environmental
Product or component typeLimit switch
Protective treatmentTC
Range of productOsiSense XC
REAChReference not containing SVHC above the threshold
Resistance across terminals<= 25 MOhm conforming to IEC 60255-7 category 3
RoHS (date code: YYWW)Compliant - since 1136 -  Schneider Electric declaration of conformity
Sensor design-
Series nameStandard format
Shock resistance50 gn (duration = 11 ms) conforming to IEC 60068-2-27
Short circuit protection10 A by gG cartridge fuse
StandardsCENELEC EN 50041 EN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14
Sustainable offer statusGreen Premium product
Switch actuationBy 30° cam
Terminals description ISO n°1(13-14)NO (21-22)NC
Type of approachLateral approach 2 directions
Type of operatorSpring return roller plunger metal
Vibration resistance25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Width40 mm

Yderliger oplysninger: Se venligst SE katalog









©Schneider Electric A/S 2025