Endestop XCKM - thermoplastic roller lever plunger - 1NC+1NO - snap - 1/2NPT


Varenr: XCKM121H7
Produktet findes ikke i SAP!

[Ithe] conventional enclosed thermal current10 A AC
[Ui] rated insulation voltage300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to IEC 60947-1 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Body materialZamak
Body typeFixed
Cable entry3 entries tapped for 1/2" NPT cable gland
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to IEC 61140
Contact code designationQ300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1 appendix A
Contacts insulation formZb
Contacts operationSnap action
Contacts type and composition1 NC + 1 NO
Depth30 mm
Device short nameXCKM
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Electrical durability5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming
Fixing modeBy the body
Head typePlunger head
Height64 mm
IK degree of protectionIK05 conforming to EN 50102
IP degree of protectionIP66 conforming to EN/IEC 60529
MaterialMetal
Maximum actuation speed1.5 m/s
Mechanical durability20000000 cycles
Minimum actuation speed0.01 m/min
Minimum force for tripping8 N
Movement of operating headLinear
Number of poles2
Number of steps1
Positive openingWith
Positive opening minimum force24 N
Product certificationsCCC CSA UL
Product end of life instructionsNeed no specific recycling operations
Product environmental profileAvailable Download Product environmental
Product or component typeLimit switch
Protective treatmentTC
Range of productOsiSense XC
REAChReference not containing SVHC above the threshold
Resistance across terminals<= 25 MOhm conforming to IEC 60255-7 category 3
RoHS (date code: YYWW)Will not be Compliant
Series nameStandard format
Shock resistance50 gn (duration = 11 ms) conforming to EN/IEC 60068-2-27
Short circuit protection10 A by gG cartridge fuse
StandardsEN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14
Sustainable offer statusNot Green Premium product
Switch actuationBy 30° cam
Terminals description ISO n°1(13-14)NO (21-22)NC
Type of approachLateral approach 1 direction
Type of operatorSpring return roller lever plunger thermoplastic
Vibration resistance25 gn (f = 10...500 Hz) conforming to EN/IEC 60068-2-6
Width64 mm

Yderliger oplysninger: Se venligst SE katalog