Navigér
Sœg

Endestop XCKM - thermoplastic roller lever plunger - 1NC+1NO - slow - 1/2NPT


Varenr: XCKM521H7
Produktet findes ikke i SAP!

[Ithe] conventional enclosed thermal current10 A AC
[Ui] rated insulation voltage300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to IEC 60947-1 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Body materialZamak
Body typeFixed
Cable entry3 entries tapped for 1/2" NPT cable gland
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to IEC 61140
Contact code designationQ300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1 appendix A
Contacts insulation formZb
Contacts operationSlow-break, break before make
Contacts type and composition1 NC + 1 NO
Depth30 mm
Device short nameXCKM
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm˛
Electrical durability5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming
Fixing modeBy the body
Head typePlunger head
Height64 mm
IK degree of protectionIK05 conforming to EN 50102
IP degree of protectionIP66 conforming to EN/IEC 60529
MaterialMetal
Maximum actuation speed1.5 m/s
Mechanical durability20000000 cycles
Minimum actuation speed6 m/min
Minimum force for tripping8 N
Movement of operating headLinear
Number of poles2
Number of steps1
Positive openingWith
Positive opening minimum force24 N
Product certificationsCCC CSA UL
Product or component typeLimit switch
Protective treatmentTC
Range of productOsiSense XC
Resistance across terminals<= 25 MOhm conforming to IEC 60255-7 category 3
Series nameStandard format
Shock resistance50 gn (duration = 11 ms) conforming to EN/IEC 60068-2-27
Short circuit protection10 A by gG cartridge fuse
StandardsEN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14
Switch actuationBy 30° cam
Terminals description ISO n°1(13-14)NO (21-22)NC
Type of approachLateral approach 1 direction
Type of operatorSpring return roller lever plunger thermoplastic
Vibration resistance25 gn (f = 10...500 Hz) conforming to EN/IEC 60068-2-6
Width64 mm

Yderliger oplysninger: Se venligst SE katalog









©Schneider Electric A/S 2025

Katalog

Hjem Info