[Ui] rated insulation voltage | 300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to EN/IEC 60947-1 300 V conforming to UL 508 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-1 6 kV conforming to IEC 60664 |
Ambient air temperature for operation | -25...70 °C |
Ambient air temperature for storage | -40...85 °C |
Body material | Zamak |
Body type | Fixed |
Cable entry | 3 entries tapped for M20 x 1.5 cable gland, cable outer diameter: 7...13 mm |
Class of protection against electric shock | Class I conforming to IEC 60536 |
Contact block per direction (control circuit) | 1 per direction |
Contact code designation | Q150, DC-13 (Ue = 125 V, Ie = 0.55 A) conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A |
Contacts insulation form | Zb |
Contacts operation | Slow-break, staggered |
Contacts type and composition | 2 x (2 NC) |
Depth | 59 mm |
Device short name | XCKMR |
Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm² |
Fixing mode | By the body |
Head material | Zamak |
Head type | Rotary head |
Height | 118 mm |
IK degree of protection | IK07 conforming to EN 50102 |
IP degree of protection | IP66 conforming to EN/IEC 60529 |
Material | Metal |
Maximum actuation speed | 1.5 m/s actuation point on the rod between 65 and 95 mm |
Maximum displacement angle | 180 ° -180 ° |
Mechanical durability | 2000000 cycles |
Minimum actuation speed | 6 m/min |
Minimum torque for tripping | 0.5 N.m |
Movement of operating head | Rotary |
Number of poles | 4 |
Number of steps | 5 electrical positions |
Positive opening | With |
Positive opening minimum torque | 0.75 N.m |
Product certifications | CCC CE CSA UL |
Product end of life instructions | Need no specific recycling operations |
Product environmental profile | Available Download Product environmental |
Product or component type | Limit switch |
Product specific application | For hoisting and mechanical handling applications |
Product weight | 0.55 kg |
Protective treatment | TC |
Range of product | OsiSense XC |
REACh | Reference not containing SVHC above the threshold |
Resistance across terminals | <= 25 MOhm conforming to IEC 60255-7 category 3 |
RoHS | Compliant - since 0936 - Schneider Electric declaration of conformity |
Series name | Special format |
Shock resistance | 50 gn conforming to EN/IEC 60068-2-27 |
Short circuit protection | 10 A by gG cartridge fuse |
Standards | EN/IEC 60947-5-1 UL 508 CSA C22.2 No 14 |
Sustainable offer status | Green Premium product |
Switch actuation | By any moving part |
Terminals description ISO n°1 | (11-12)NC (21-22)NC |
Type of approach | Lateral approach 2 directions |
Type of operator | Stay put crossed rods lever metal (square rod 6 mm, L = 200 mm) |
Vibration resistance | 25 gn (f = 10...500 Hz) conforming to EN/IEC 60068-2-6 |
Width | 200 mm |