Navigér
Sœg

Endestop XCKT - metal end plunger - 1NC+1NO - slow - 1/2NPT


Varenr: XCKT2510N12
Produktet findes ikke i SAP!

[Ui] rated insulation voltage300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to IEC 60947-1 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Body materialPlastic
Body typeFixed
Cable entry2 entries tapped for 1/2" NPT cable gland
Class of protection against electric shockClass II conforming to NF C 20-030 Class II conforming to IEC 61140
Contact code designationQ300, DC-13 (Ue = 250 V 0.27 A conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
Contacts insulation formZb
Contacts operationSlow-break, break before make
Contacts type and composition1 NC + 1 NO
Device short nameXCKT
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm˛
Electrical durability5000000 cycles, DC-13, 48 V, 9 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 13 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles
Fixing modeBy the body
Head materialZamak
Head typePlunger head
IK degree of protectionIK04 conforming to EN 50102
IP degree of protectionIP67 conforming to IEC 60529 IP66 conforming to IEC 60529
MaterialPlastic
Maximum actuation speed0.5 m/s
Mechanical durability15000000 cycles
Minimum actuation speed6 m/min
Minimum force for tripping15 N
Movement of operating headLinear
Number of poles2
Positive openingWith
Positive opening minimum force45 N
Product certificationsCCC CSA UL
Product end of life instructionsAvailable
Product environmental profileAvailable
Product or component typeLimit switch
Protective treatmentTC
Range of productOsiSense XC
REAChReference not containing SVHC above the threshold
Repeat accuracy0.1 mm on the tripping points with 1 million operating cycles
Resistance across terminals<= 25 MOhm conforming to IEC 60255-7 category 3
RoHS (date code: YYWW)Will be Compliant on 4Q2014
Sensor designCompact form B conforming to CENELEC EN 50047
Series nameStandard format
Shock resistance50 gn (duration = 11 ms) conforming to IEC 60068-2-27
Short circuit protection10 A cartridge fuse gG
StandardsEN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14
Sustainable offer statusNot Green Premium product
Switch actuationOn end
Type of approachVertical approach 1 direction
Type of operatorSpring return plunger metal
Vibration resistance25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6

Yderliger oplysninger: Se venligst SE katalog









©Schneider Electric A/S 2025

Katalog