Endestop XCMD - thermoplastic roller lever - 1NC+1NO - snap - 1 meter


Varenr:XCMD2115L1
El nr:7524702298
EAN13 nr:3389110218411
Pakning:1stk

[Ui] rated insulation voltage300 V degree of pollution 3 conforming to CSA C22.2 No 14 400 V degree of pollution 3 conforming to IEC 60947-5-1 300 V degree of pollution 3 conforming to UL 508
[Uimp] rated impulse withstand voltage4 kV conforming to IEC 60947-1 4 kV conforming to IEC 60664
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Body materialZamak
Body typeFixed
Cable composition5 x 0.75 mm²
Cable length1 m
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to IEC 61140
Contact code designationR300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 appendix A B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A
Contacts insulation formZb
Contacts operationSnap action
Contacts type and composition1 NC + 1 NO
Depth16 mm
Device short nameXCMD
Electrical connectionRemovable cable connector
Fixing modeBy the body
Head materialZamak
Head typeRotary head
Height50 mm
IK degree of protectionIK06 conforming to EN 50102
IP degree of protectionIP68 conforming to IEC 60529 IP67 conforming to IEC 60529 IP66 conforming to IEC 60529
MaterialMetal
Maximum actuation speed1.5 m/s
Mechanical durability10000000 cycles
Electrical durability5000000 cycles, DC-13, 48 V, 2 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 3 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles,
Minimum force for tripping0.1 N
Movement of operating headRotary
Number of poles2
Positive openingWith
Positive opening minimum force0.5 N
Product certificationsCCC CSA UL
Product end of life instructionsAvailable Download End of life manual
Product environmental profileAvailable Download Product environmental
Product or component typeLimit switch
Product weight0.22 kg
Protective treatmentTC
Range of productOsiSense XC
REAChReference not containing SVHC above the threshold
Resistance across terminals<= 25 MOhm conforming to IEC 60255-7 category 3
RoHS (date code: YYWW)Compliant - since 1002 -  Schneider Electric declaration of conformity
Sensor designMiniature
Series nameStandard format
Shock resistance25 gn (duration = 18 ms) conforming to IEC 60068-2-27
Short circuit protection6 A by gG cartridge fuse
StandardsEN/IEC 60204-1 EN/IEC 60947-5-1 UL 508 CSA C22.2 No 14
Sustainable offer statusGreen Premium product
Switch actuationBy 30° cam
Tracks24/31 mm
Type of approachLateral approach 2 directions
Type of operatorSpring return roller lever thermoplastic
Vibration resistance5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Width30 mm
Wire insulation materialPvR