[Ui] rated insulation voltage | 300 V degree of pollution 3 conforming to CSA C22.2 No 14 400 V degree of pollution 3 conforming to IEC 60947-5-1 300 V degree of pollution 3 conforming to UL 508 |
[Uimp] rated impulse withstand voltage | 4 kV conforming to IEC 60947-1 4 kV conforming to IEC 60664 |
Ambient air temperature for operation | -25...70 °C |
Ambient air temperature for storage | -40...70 °C |
Body material | Zamak |
Body type | Fixed |
Cable composition | 5 x 0.75 mm² |
Cable length | 5 m |
Class of protection against electric shock | Class I conforming to NF C 20-030 Class I conforming to IEC 61140 |
Contact code designation | R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 appendix A B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A |
Contacts insulation form | Zb |
Contacts operation | Slow-break |
Contacts type and composition | 1 NC + 1 NO |
Depth | 16 mm |
Device short name | XCMD |
Electrical connection | Removable cable connector |
Electrical durability | 5000000 cycles, DC-13, 48 V, 2 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 3 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, |
Fixing mode | By the head |
Head material | Zamak |
Head type | M12 plunger head |
Height | 50 mm |
IK degree of protection | IK06 conforming to EN 50102 |
IP degree of protection | IP68 conforming to IEC 60529 IP67 conforming to IEC 60529 IP66 conforming to IEC 60529 |
Material | Metal |
Maximum actuation speed | 10 cm/s |
Mechanical durability | 10000000 cycles |
Minimum force for tripping | 7 N |
Movement of operating head | Linear |
Number of poles | 2 |
Positive opening | With |
Positive opening minimum force | 35 N |
Product certifications | CCC CSA UL |
Product end of life instructions | Available Download End of life manual |
Product environmental profile | Available Download Product environmental |
Product or component type | Limit switch |
Product weight | 0.205 kg |
Protective treatment | TC |
Range of product | OsiSense XC |
REACh | Reference not containing SVHC above the threshold |
Resistance across terminals | <= 25 MOhm conforming to IEC 60255-7 category 3 |
RoHS (date code: YYWW) | Compliant - since 1002 - Schneider Electric declaration of conformity |
Sensor design | Miniature |
Series name | Standard format |
Shock resistance | 25 gn (duration = 18 ms) conforming to IEC 60068-2-27 |
Short circuit protection | 6 A by gG cartridge fuse |
Standards | EN/IEC 60204-1 EN/IEC 60947-5-1 UL 508 CSA C22.2 No 14 |
Sustainable offer status | Green Premium product |
Switch actuation | By 30° cam |
Type of approach | Lateral approach 2 directions |
Type of operator | Spring return roller plunger metal |
Vibration resistance | 25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
Width | 30 mm |
Wire insulation material | PvR |