[Ui] rated insulation voltage300 V degree of pollution 3 conforming to CSA C22.2 No 14 400 V degree of pollution 3 conforming to IEC 60947-5-1 300 V degree of pollution 3 conforming to UL 508
[Uimp] rated impulse withstand voltage4 kV conforming to IEC 60947-1 4 kV conforming to IEC 60664
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Body materialZamak
Body typeFixed
Cable composition7 x 0.5 mm²
Cable length2 m
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to IEC 61140
Contact code designationR300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 appendix A B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A
Contacts insulation formZb
Contacts operationSnap action
Contacts type and composition2 NC + 1 NO
Depth16 mm
Device short nameXCMD
Electrical connectionRemovable cable connector
Electrical durability5000000 cycles, DC-13, 48 V, 2 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 3 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles,
Fixing modeBy the body
Head materialZamak
Head typePlunger head
Height50 mm
IK degree of protectionIK06 conforming to EN 50102
IP degree of protectionIP68 conforming to IEC 60529 IP67 conforming to IEC 60529 IP66 conforming to IEC 60529
MaterialMetal
Maximum actuation speed0.5 m/s
Mechanical durability10000000 cycles
Minimum actuation speed0.01 m/min
Minimum force for tripping8.5 N
Movement of operating headLinear
Number of poles3
Positive openingWith
Positive opening minimum force35 N
Product certificationsCCC CSA UL
Product end of life instructionsAvailable Download End of life manual
Product environmental profileAvailable Download Product environmental
Product or component typeLimit switch
Product weight0.185 kg
Protective treatmentTC
Range of productOsiSense XC
REAChReference not containing SVHC above the threshold
Resistance across terminals<= 25 MOhm conforming to IEC 60255-7 category 3
RoHS (date code: YYWW)Compliant - since 1038 -  Schneider Electric declaration of conformity
Sensor designMiniature
Series nameStandard format
Shock resistance25 gn (duration = 18 ms) conforming to IEC 60068-2-27
Short circuit protection6 A by gG cartridge fuse
StandardsEN/IEC 60204-1 EN/IEC 60947-5-1 UL 508 CSA C22.2 No 14
Sustainable offer statusGreen Premium product
Switch actuationOn end
Type of approachVertical approach 1 direction
Type of operatorSpring return plunger metal
Vibration resistance25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Width30 mm
Wire insulation materialPvR