 |
[Ui] rated insulation voltage | 300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to VDE 0110 500 V degree of pollution 3 conforming to IEC 60947-1 300 V conforming to UL 508 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664 |
Ambient air temperature for operation | -25...70 °C |
Ambient air temperature for storage | -40...70 °C |
Body material | Zinc alloy |
Body type | Fixed |
Cable entry | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9...12 mm conforming to NF C 68-300 |
Class of protection against electric shock | Class I conforming to NF C 20-030 Class I conforming to IEC 61140 |
Contact block per direction (control circuit) | 2 per direction |
Contact code designation | Q300, DC-13 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1 appendix A |
Contacts insulation form | Zb |
Contacts operation | Snap action |
Contacts type and composition | 2 x (1 NC + 1 NO) |
Depth | 75 mm |
Device short name | XCR |
Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² |
Electrical durability | 5000000 cycles, DC-13 inductive load type, 48 V, 10 W, load factor: 0.5, operating rate: <= 60 cyc/mn IEC 60947-5-1 appendix C 5000000 cycles, DC-13 inductive load type, 24 V, 7 W, load factor: 0.5, operating rate: <= 60 cyc/mn IEC 60947-5-1 appendix C 50 |
Fixing mode | By the body |
Head type | Rotary head |
Height | 95 mm |
IP degree of protection | IP54 conforming to IEC 60529 |
Material | Metal |
Maximum actuation speed | 1.5 m/s |
Maximum displacement angle | 55 ° -55 ° |
Mechanical durability | 10000000 cycles |
Minimum actuation speed | 0.01 m/min |
Minimum torque for tripping | 0.45 N.m |
Movement of operating head | Rotary |
Number of poles | 4 |
Number of steps | 1 |
Positive opening | With |
Positive opening minimum torque | 0.75 N.m |
Product certifications | CCC CSA |
Product end of life instructions | Need no specific recycling operations |
Product environmental profile | Available Download Product environmental |
Product or component type | Limit switch |
Product specific application | For hoisting and mechanical handling applications |
Product weight | 1.11 kg |
Protective treatment | TC |
Range of product | OsiSense XC |
REACh | Reference not containing SVHC above the threshold |
Resistance across terminals | <= 25 MOhm conforming to IEC 60255-7 category 3 |
RoHS | Will be Compliant on 4Q2014 |
Sensor design | - |
Series name | Special format |
Shock resistance | 68 gn conforming to IEC 60068-2-27 |
Short circuit protection | 10 A by gG cartridge fuse |
Standards | EN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 NF C 79-130 CSA C22.2 No 14 |
Sustainable offer status | Not Green Premium product |
Switch actuation | By any moving part |
Terminals description ISO n°1 | (13-14)NO (21-22)NC |
Type of approach | 2 directions lateral approach |
Type of operator | Metal spring return rod lever (square rod 6 mm) |
Vibration resistance | 9 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
Width | 85 mm |