Navigér
Sœg

Endestop XCR-F - square rod 6 meter crossed - 2 x (1 NC + 1 NO)


Varenr:XCRF171EX
El nr:7524705664
EAN13 nr:3389118028005
Pakning:1stk

[Ui] rated insulation voltage500 V, pollution degree: 3 conforming to VDE 0110 500 V, pollution degree: 3 conforming to IEC 60947-1 500 V conforming to NF C 20-040 group C 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664
Ambient air temperature for operation-20...60 °C
Body typeFixed
Cable entry number1 tapped entry (Pg 13.5) for cable gland (included), cable outer diameter: 9...12 mm
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to IEC 60536
Contact block per direction (control circuit)1 per direction
Contacts insulation formZb
Contacts operationSnap action
Contacts type and composition2 x (1 NC + 1 NO)
Depth75 mm
Device short nameXCR
Dust zoneZone 21 - 22
Electrical connectionScrew-clamp terminals, 1 x 0.34...2 x 1.5 mm²
Fixing modeBy the body
Head typeRotary head
Height95 mm
Contact code designationQ300, DC-13 (250 V, Ie = 0.27 A) conforming to IEC 60947-5-1 appendix A Q300, DC-13 (250 V, Ie = 0.27 A) conforming to EN 60947-5-1 A300, AC-15 (240 V, Ie = 3 A) conforming to IEC 60947-5-1 appendix A A300, AC-15 (240 V, Ie = 3 A) conforming to EN 60947-5
Electrical durability5000000 cycles DC-13 48 V 7 W, <= 60 cyc/mn load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive DC 5000000 cycles DC-13 24 V 10 W, <= 60 cyc/mn load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive DC 5000000 cycles DC-13 120 V 4
IP degree of protectionIP65 conforming to IEC 60529
MarkingII2 D-Ex tb IIIC T85°C Db IP66/67
MaterialMetal
Maximum actuation speed1.5 m/s
Maximum displacement angle90 ° -90 °
Mechanical durability10000000 cycles
Minimum actuation speed0.01 m/min
Minimum force for tripping0.7 N
Minimum torque for tripping0.6 N.m
Movement of operating headRotary
Number of poles4
Number of steps1
Positive openingWith
Product certificationsINERIS 04ATEX0014X
Product end of life instructionsNeed no specific recycling operations
Product environmental profileAvailable Download Product environmental
Product or component typeLimit switch
Product specific applicationFor hoisting and mechanical handling applications
Protective treatmentTC
Range of productOsiSense ATEX D
REAChReference not containing SVHC above the threshold
Resistance across terminals<= 25 MOhm conforming to NF C 93-050 method A <= 25 MOhm conforming to IEC 60255-7 category 3
RoHSWill be Compliant on 4Q2014
Series nameSpecial format
Shock resistance68 gn conforming to IEC 60068-2-27
Short circuit protection10 A cartridge fuse, type gG
StandardsDirective ATEX 94/9/EC EN/IEC 60079-0 EN/IEC 60079-31
Sustainable offer statusNot Green Premium product
Switch actuationBy any moving part
Type of approachLateral approach, 2 directions
Type of operatorMetal stay put crossed rods lever, square rod 6 mm
Vibration resistance9 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Width85 mm

Yderliger oplysninger: Se venligst SE katalog