Navigér
Sœg

Endestop til transportbånd


Varenr:XCRT115
El nr:7524016434
EAN13 nr:3389110652499
Pakning:1stk

[Ui] rated insulation voltage300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to VDE 0110 500 V degree of pollution 3 conforming to IEC 60947-1 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Body materialZinc alloy
Body typeFixed
Cable entry1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9...12 mm conforming to NF C 68-300
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to IEC 61140
Contact block per direction (control circuit)2 per direction
Contact code designationQ300, DC-13 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1 appendix A
Contacts insulation formZa
Contacts operationSnap action
Contacts type and composition2 C/O
Depth75 mm
Device short nameXCRT
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Fixing modeBy the body
Head typeRotary head
Height95 mm
IP degree of protectionIP65 conforming to IEC 60529
MaterialMetal
Maximum displacement angle90 ° -90 °
Mechanical durability300000 cycles
Minimum actuation speed0.01 m/min
Minimum torque for tripping1 N.m
Electrical durability5000000 cycles, DC-13 inductive load type, 48 V, 10 W, load factor: 0.5, operating rate: <= 60 cyc/mn IEC 60947-5-1 appendix C 5000000 cycles, DC-13 inductive load type, 24 V, 7 W, load factor: 0.5, operating rate: <= 60 cyc/mn IEC 60947-5-1 appendix C 50
Movement of operating headRotary
Number of poles2
Number of steps2
Positive openingWithout
Product end of life instructionsNeed no specific recycling operations
Product environmental profileAvailable Download Product environmental
Product or component typeLimit switch
Product specific applicationFor conveyor belt shift monitoring
Product weight1.17 kg
Protective treatmentTC
Range of productOsiSense XC
REAChReference not containing SVHC above the threshold
Resistance across terminals<= 25 MOhm conforming to IEC 60255-7 category 3
RoHSCompliant - since 1019 -  Schneider Electric declaration of conformity
Sensor design-
Series nameSpecial format
Shock resistance30 gn (duration = 18 ms) conforming to IEC 60068-2-27
Short circuit protection10 A by gG cartridge fuse
StandardsEN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 NF C 79-130 CSA C22.2 No 14
Sustainable offer statusGreen Premium product
Switch actuationBy conveyor belt
Terminals description ISO n°1(11-12)NC (13-14)NO
Tripping angle18 ° for stopping of the conveyor belt 10 ° for fault signalling
Type of approach2 directions lateral approach
Type of operatorZinc plated steel spring return roller (with lever)
Vibration resistance9 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Width85 mm

Yderliger oplysninger: Se venligst SE katalog









©Schneider Electric A/S 2025

Katalog

Hjem Info