[Ui] rated insulation voltage | 500 V, pollution degree: 3 conforming to VDE 0110 500 V, pollution degree: 3 conforming to IEC 60947-1 500 V conforming to NF C 20-040 group C 300 V conforming to UL 508 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664 |
Ambient air temperature for operation | -20...60 °C |
Body material | Zinc alloy |
Body type | Fixed |
Cable entry number | 1 tapped entry (Pg 13.5) for cable gland (included), cable outer diameter: 9...12 mm |
Class of protection against electric shock | Class I conforming to NF C 20-030 Class I conforming to IEC 60536 |
Contact block per direction (control circuit) | 1 per direction |
Contact code designation | Q300, DC-13 (250 V, Ie = 0.27 A) conforming to IEC 60947-5-1 appendix A Q300, DC-13 (250 V, Ie = 0.27 A) conforming to EN 60947-5-1 A300, AC-15 (240 V, Ie = 3 A) conforming to IEC 60947-5-1 appendix A A300, AC-15 (240 V, Ie = 3 A) conforming to EN 60947-5 |
Contacts insulation form | Za |
Contacts operation | Snap action |
Contacts type and composition | 2 x 1 C/O |
Depth | 75 mm |
Device short name | XCR |
Dust zone | Zone 21 - 22 |
Electrical connection | Screw-clamp terminals, 1 x 0.5...2 x 2.5 mm² |
Fixing mode | By the body |
Head type | Rotary head |
Height | 95 mm |
IP degree of protection | IP65 conforming to IEC 60529 |
Marking | II2 D-Ex tb IIIC T85°C Db IP66/67 |
Material | Metal |
Maximum actuation speed | 1.5 m/s |
Maximum displacement angle | 90 ° -90 ° |
Mechanical durability | 300000 cycles |
Minimum actuation speed | 0.01 m/min |
Minimum torque for tripping | 1 N.m |
Electrical durability | 5000000 cycles DC-13 48 V 7 W, <= 3600 cyc/mn load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive DC 5000000 cycles DC-13 24 V 10 W, <= 3600 cyc/mn load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive DC 5000000 cycles DC-13 120 |
Movement of operating head | Rotary |
Number of poles | 2 |
Number of steps | 2 |
Positive opening | With |
Product certifications | INERIS 04ATEX0014X |
Product end of life instructions | Need no specific recycling operations |
Product environmental profile | Available Download Product environmental |
Product or component type | Limit switch |
Product specific application | For conveyor belt shift monitoring |
Protective treatment | TC |
Range of product | OsiSense ATEX D |
REACh | Reference not containing SVHC above the threshold |
Resistance across terminals | <= 25 MOhm conforming to NF C 93-050 method A <= 25 MOhm conforming to IEC 60255-7 category 3 |
RoHS | Compliant - since 1019 - Schneider Electric declaration of conformity |
Series name | Special format |
Shock resistance | 30 gn for 18 ms conforming to IEC 60068-2-27 |
Short circuit protection | 10 A cartridge fuse, type gG |
Standards | Directive ATEX 94/9/EC EN/IEC 60079-0 EN/IEC 60079-31 |
Sustainable offer status | Green Premium product |
Switch actuation | By conveyor belt |
Tripping angle | 18 ° stopping of the conveyor belt 10 ° fault signalling |
Type of approach | Lateral approach, 2 directions |
Type of operator | Zinc plated steel spring return roller, with lever |
Vibration resistance | 9 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
Width | 85 mm |