[Ie] rated operational current | <= 100 A |
[Sa] assured operating distance | 8 mm |
[Sar] assured tripping distance | 20 mm |
[Ue] rated operational voltage | 24 V DC |
[Ui] rated insulation voltage | 100 V DC |
[Uimp] rated impulse withstand voltage | 2.5 kV conforming to EN/IEC 60947-5-1 |
Ambient air temperature for operation | -25...85 °C |
Ambient air temperature for storage | -40...85 °C |
Approach directions | 3 directions |
Breaking capacity | <= 10 VA |
Cable composition | 6 x 0.25 mm² |
Cable length | 5 m |
Cable material | PVC |
Class of protection against electric shock | Class II conforming to IEC 60536 |
Component name | XCSDMP |
Contacts material | Rhodium |
Contacts operation | 1 NO staggered |
Contacts type and composition | 1 NC + 2 NO |
Depth | 13 mm |
Design | Rectangular, standard |
Electrical connection | Pre-cabled |
Electrical durability | 1200000 cycles |
Enclosure material | Thermoplastic PBT |
Height | 88 mm |
Insulation resistance | 1000 MOhm |
IP degree of protection | IP67 conforming to IEC 60529 IP66 conforming to IEC 60529 |
Material | Plastic |
Maximum switching voltage | DC |
Number of poles | 3 |
Product certifications | BG CSA UL |
Product or component type | Coded magnetic switch |
Product weight | 0.18 kg |
Protective treatment | TH |
Range of product | Preventa Safety detection |
REACh | Reference not containing SVHC above the threshold |
Resistance across terminals | 10 Ohm |
RoHS (date code: YYWW) | Compliant - since 0729 - Schneider Electric declaration of conformity |
Safety level | Can reach SIL 3 (with the appropriate monitoring system and correctly wired) conforming to EN/IEC 61508 Can reach PL = e (with the appropriate monitoring system and correctly wired) conforming to EN/ISO 13849-1 Can reach category 4 (with the appropriate m |
Safety reliability data | B10d = 50000000 (value given for a life time of 20 years limited by mechanical or contact wear) |
Sensitivity to magnetic fields | >= 0.3 mT |
Shock resistance | 30 gn for 11 ms conforming to IEC 60068-2-27 |
Short circuit protection | 500 mA external cartridge fuse type gG (gl) |
Size | 88 x 25 x 13 mm |
Standards | EN 1088 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 ISO 14119 UL 508 CSA C22.2 No 14 |
Sustainable offer status | Not Green Premium product |
Switching capacity in mA | 0.1...100 mA |
Switching frequency | 150 Hz |
Vibration resistance | 10 gn (f = 10...150 Hz) conforming to IEC 60068-2-6 |
Width | 25 mm |