[Ie] rated operational current1.5 A at 240 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1 3 A at 120 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1 0.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 0.55 A at 125 V uti
[Ithe] conventional enclosed thermal current6 A
[Ui] rated insulation voltage250 V for signalling circuit conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-5-1
[Us] solenoid rated supply  voltage220/240 V (- 20...10 %)
Actuator force for extraction>= 20 N
Actutr forcible withdrawal rtc2000 N
Ambient air temperature for operation-25...40 °C
Ambient air temperature for storage-40...70 °C
Body materialZamak
Cable entry2 entries tapped 1/2" NPT
Class of protection against electric shockClass I conforming to EN/IEC 60536
Component nameXCSE
Contacts operationSlow-break, break before make
Contacts type and composition2 NC + 1 NO
Depth44 mm
DesignRectangular
Electrical connectionTerminal, 1 x 0.5...2 x 1.5 mm² with or without cable end
Electromagnet interlockingLocking on energisation and unlocking on de-energisation of solenoid
Head materialZamak
Head typeKey operated turret head
Height146 mm
IP degree of protectionIP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Load factor1
Local signalling2 LEDs green or orange (guard open/guard closed and locked)
Locking options descriptionWith interlocking, locking by solenoid
MaterialMetal
Maximum actuation speed0.5 m/s
Mechanical durability>= 1000000 cycles
Minimum actuation speed0.01 m/s
Number of poles3
Operating rate10 cyc/mn for maximum durability
Positive openingWith NC contact
Power consumption in VA10 VA (sealed) 10 VA (inrush)
Product certificationsCSA UL
Product end of life instructionsAvailable Download End of life manual
Product environmental profileAvailable Download Product environmental
Product or component typeSafety switch
Product weight1.14 kg
Protection typeOvervoltage protection for signalling circuit
Protective treatmentTC
Range of productPreventa Safety detection
REAChReference not containing SVHC above the threshold
RoHS (date code: YYWW)Compliant - since 1150 -  Schneider Electric declaration of conformity
Safety levelCan reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monito
Safety reliability dataB10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear)
Shock resistance10 gn for 11 ms conforming to IEC 60068-2-27
Short circuit protection10 A cartridge fuse type gG (gl)
Signalling circuit consumption7 mA
Signalling circuit typeAC
Signalling circuit voltage110/240 V (voltage limits: 95...264 V)
Solenoid contacts type and composition1 NC + 1 NO (slow-break, simultaneous)
StandardsEN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 UL 508 CSA C22.2 No 14
Supply frequency50/60 Hz
Supply voltage typeAC/DC
Sustainable offer statusGreen Premium product
Vibration resistance5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6