[Ie] rated operational current | 1.5 A at 240 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1 3 A at 120 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1 0.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 0.55 A at 125 V uti |
[Ithe] conventional enclosed thermal current | 6 A |
[Ui] rated insulation voltage | 250 V for signalling circuit conforming to EN/IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-5-1 |
[Us] solenoid rated supply voltage | 110/120 V (- 20...10 %) |
Actuator force for extraction | >= 20 N |
Actutr forcible withdrawal rtc | 2000 N |
Ambient air temperature for operation | -25...40 °C |
Ambient air temperature for storage | -40...70 °C |
Body material | Zamak |
Cable entry | 2 entries tapped Pg 13.5 |
Cable outer diameter | 9...12 mm |
Class of protection against electric shock | Class I conforming to EN/IEC 60536 |
Component name | XCSE |
Contacts operation | Slow-break, simultaneous |
Contacts type and composition | 3 NC |
Depth | 44 mm |
Design | Rectangular |
Electrical connection | Terminal, 1 x 0.5...2 x 1.5 mm² with or without cable end |
Electromagnet interlocking | Locking on energisation and unlocking on de-energisation of solenoid |
Head material | Zamak |
Head type | Key operated turret head |
Height | 146 mm |
IP degree of protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
Load factor | 1 |
Local signalling | 1 LED green (guard closed and locked) |
Locking options description | With interlocking, locking by solenoid |
Material | Metal |
Maximum actuation speed | 0.5 m/s |
Mechanical durability | >= 1000000 cycles |
Minimum actuation speed | 0.01 m/s |
Number of poles | 3 |
Operating rate | 10 cyc/mn for maximum durability |
Positive opening | With NC contact |
Power consumption in VA | 10 VA (sealed) 10 VA (inrush) |
Product certifications | CSA UL |
Product end of life instructions | Available Download End of life manual |
Product environmental profile | Available Download Product environmental |
Product or component type | Safety switch |
Product weight | 1.14 kg |
Protection type | Overvoltage protection for signalling circuit |
Protective treatment | TC |
Range of product | Preventa Safety detection |
REACh | Reference not containing SVHC above the threshold |
RoHS (date code: YYWW) | Compliant - since 1150 - Schneider Electric declaration of conformity |
Safety level | Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monito |
Safety reliability data | B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear) |
Shock resistance | 10 gn for 11 ms conforming to IEC 60068-2-27 |
Short circuit protection | 10 A cartridge fuse type gG (gl) |
Signalling circuit consumption | 7 mA |
Signalling circuit type | AC |
Signalling circuit voltage | 110/240 V (voltage limits: 95...264 V) |
Solenoid contacts type and composition | 1 NC + 1 NO (slow-break, simultaneous) |
Standards | EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 UL 508 CSA C22.2 No 14 |
Supply frequency | 50/60 Hz |
Supply voltage type | AC/DC |
Sustainable offer status | Green Premium product |
Vibration resistance | 5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
Width | 98 mm |