[Ie] rated operational current | 0.75 A at 240 V utilisation category AC-15, C300 conforming to EN/IEC 60947-5-1 0.55 A at 24 V utilisation category DC-13, R300 conforming to EN/IEC 60947-5-1 |
[Ithe] conventional enclosed thermal current | 4 A |
[Ui] rated insulation voltage | 250 V (degree of pollution: 3) conforming to EN/IEC 60947-1 300 V conforming to CSA C22.2 No 14 300 V conforming to UL 508 |
[Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60947-5-1 |
[Us] solenoid rated supply voltage | 24 V (- 15...10 %) |
Actuator force for extraction | >= 20 N |
Actutr forcible withdrawal rtc | <= 1400 N |
Ambient air temperature for operation | -25...60 °C |
Ambient air temperature for storage | -40...70 °C |
Body material | PA (polyamide) |
Cable entry | 3 entries tapped M20 x 1.5 |
Cable outer diameter | 7...13 mm |
Class of protection against electric shock | Class II conforming to EN/IEC 60536 |
Component name | XCSLE |
Contacts operation | Slow-break, break before make |
Contacts type and composition | 2 NC + 1 NO |
Depth | 51 mm |
Design | Slim |
Electrical connection | Spring terminal, 2 x 0.5 mm² flexible cables with 13 mm bared ends Spring terminal, 1 x 1.5 mm² flexible or solid cable |
Electromagnet interlocking | Locking on de-energisation and unlocking on energisation of solenoid |
Head material | PA (polyamide) |
Head type | Key operated turret head |
Height | 205 mm |
Insulation | Double insulated |
IP degree of protection | IP67 IP66 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
Load factor | 1 |
Local signalling | 1 LED green (actuator inserted and locked) 1 LED orange (actuator withdrawn) |
Locking options description | With interlocking, locking by solenoid |
Material | Plastic |
Maximum actuation speed | 0.5 m/s |
Maximum load current | <= 15 A |
Mechanical durability | 1000000 cycles |
Minimum actuation speed | 0.01 m/s |
Minimum switching current | 10 mA at 20 °C |
Minimum switching voltage | 17 V |
Number of poles | 3 |
Operating rate | 10 cyc/mn for maximum durability |
Positive opening | With NC contact |
Product certifications | CSA TÜV UL |
Product or component type | Safety switch |
Product weight | 0.53 kg |
Protective treatment | TC |
Range of product | Preventa Safety detection |
Resistance to mechanical impact | 4.9 J without partition 1.2 J against the partition |
Safety level | Can reach SIL 3 conforming to EN/IEC 61508 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849- |
Safety reliability data | B10d = 5500000 (value given for a life time of 20 years limited by mechanical or contact wear) |
Shock resistance | 10 gn for 11 ms conforming to IEC 60068-2-27 |
Short circuit protection | 6 A type fast blow 4 A cartridge fuse type gG (gl) |
Signalling circuit type | AC/DC |
Signalling circuit voltage | 24 V |
Solenoid contacts type and composition | 2 NC + 1 NO (slow-break, break before make) |
Standards | EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/IEC 62061 EN/ISO 13849-1 UL 508 CSA C22.2 No 14 |
Supply frequency | 50/60 Hz |
Supply voltage type | AC/DC |
Vibration resistance | 5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
Width | 44 mm |