[Ie] rated operational current | 0.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 0.55 A at 125 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 3 A at 240 V utilisation category AC-15, A300 conforming to EN/IEC 60947-5-1 6 A at 120 V utili |
[Ithe] conventional enclosed thermal current | 10 A |
[Ui] rated insulation voltage | 300 V conforming to CSA C22.2 No 14 500 V conforming to EN/IEC 60947-1 300 V conforming to UL 508 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-5-1 |
Actutr forcible withdrawal rtc | 10 N |
Ambient air temperature for operation | -25...70 °C |
Ambient air temperature for storage | -40...70 °C |
Body material | PA (polyamide) |
Cable entry | 1 entry tapped Pg 11 |
Cable outer diameter | 7...10 mm |
Class of protection against electric shock | Class II conforming to EN/IEC 60536 |
Component name | XCSPA |
Contacts operation | Slow-break, simultaneous |
Contacts type and composition | 2 NC |
Depth | 30 mm |
Design | Compact |
Electrical connection | Terminal, 1 x 0.5...2 x 1.5 mm² with or without cable end |
Head material | PA (polyamide) |
Head type | Key operated turret head |
Height | 94 mm |
Insulation | Double insulated |
IP degree of protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
Locking options description | Without locking of actuator |
Material | Plastic |
Maximum actuation speed | 0.5 m/s |
Mechanical durability | >= 1000000 cycles |
Minimum actuation speed | 0.01 m/s |
Number of poles | 2 |
Operating rate | 10 cyc/mn for maximum durability |
Positive opening | With NC contact |
Positive opening minimum force | 15 N |
Product certifications | CSA UL |
Product end of life instructions | Available Download End of life manual |
Product environmental profile | Available Download Product environmental |
Product or component type | Safety switch |
Product weight | 0.11 kg |
Protective treatment | TC |
Range of product | Preventa Safety detection |
REACh | Reference not containing SVHC above the threshold |
RoHS (date code: YYWW) | Compliant - since 0919 - Schneider Electric declaration of conformity |
Safety reliability data | B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear) |
Shock resistance | 10 gn for 11 ms conforming to IEC 60068-2-27 |
Short circuit protection | 10 A cartridge fuse type gG (gl) |
Standards | EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 UL 508 CSA C22.2 No 14 |
Safety level | Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monito |
Sustainable offer status | Green Premium product |
Vibration resistance | 5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
Width | 30 mm |