[Ithe] conventional enclosed thermal current | 10 A |
[Ui] rated insulation voltage | 500 V (degree of pollution: 3) conforming to EN/IEC 60947-1 300 V conforming to CSA C22.2 No 14 300 V conforming to UL 508 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-5-1 |
Ambient air temperature for operation | -25...70 °C |
Ambient air temperature for storage | -40...70 °C |
Cable entry | 1 entry tapped Pg 11 |
Cable outer diameter | 7...10 mm |
Clamping connection capacity | 1 x 0.5...2 x 1.5 mm² with or without cable end |
Class of protection against electric shock | Class II conforming to IEC 60536 |
Component name | XCSPR |
Contact code designation | Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 Q300, DC-13 (Ue = 125 V, Ie = 0.55 A) conforming to EN/IEC 60947-5-1 A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1 A300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN |
Contacts operation | Slow-break, break before make |
Contacts type and composition | 1 NC + 1 NO |
Depth | 110 mm |
Electrical connection | Terminal |
Enclosure material | Polyamide PA66 fibre glass impregnated |
Head type | Turret head rotary axis |
Height | 96 mm |
Insulation | Double insulated |
IP degree of protection | IP67 conforming to IEC 60529 |
Lever material | Stainless steel |
Material | Plastic |
Mechanical durability | 1000000 cycles |
Minimum torque for tripping | 0.1 N.m |
Number of poles | 2 |
Positive opening | With NC contact |
Positive opening minimum torque | 0.25 N.m |
Product certifications | BG CSA UL |
Product end of life instructions | Available Download End of life manual |
Product environmental profile | Available Download Product environmental |
Product or component type | Guard switch |
Product weight | 0.137 kg |
Protective treatment | TC TH |
Range of product | Preventa Safety detection |
REACh | Reference not containing SVHC above the threshold |
Resistance across terminals | <= 30 mOhm conforming to EN/IEC 60947-5-4 |
RoHS (date code: YYWW) | Compliant - since 1136 - Schneider Electric declaration of conformity |
Safety level | Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monitorin |
Safety reliability data | B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear) |
Shock resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 |
Short circuit protection | 10 A cartridge fuse type gG (gl) |
Standards | EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/IEC 60947-5-4 EN/ISO 12100 UL 508 CSA C22.2 No 14 |
Sustainable offer status | Green Premium product |
Tripping angle | 5 ° |
Type of operator | Spindle 80 mm |
Vibration resistance | 50 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
Width | 30 mm |