Navigér
Sœg

Tryktransmitter 0-400bar NPN M12 TQ


Varenr:XMLG400D31TQ
El nr:7524293710
EAN13 nr:3389118048126
Pakning:1stk

[Uimp] rated impulse withstand voltage0.5 kV
[Us] rated supply voltage12/24 V DC, voltage limits: 8...33 V
Adjustable range of switching point on falling pressure20...388 bar
Adjustable range of switching point on rising pressure32...400 bar
Ambient air temperature for operation-15...85 °C
Ambient air temperature for storage-40...85 °C
Controlled fluidFresh water (0...125 °C) Hydraulic oil (-15...125 °C) Corrosive fluid (-15...125 °C) Air (-15...125 °C)
Current consumption< 4 mA
Destruction pressure900 bar
Diameter22.8 mm
Discrete output typeSolid state NPN, 1 NC
Drift of the sensitivity+/- 0.015 % of measuring range/°C
Drift of the zero point+/- 0.015 % of measuring range/°C
Electrical circuit typeControl circuit
Electrical connection3 pins 1 male connector M12
Fluid connection typeG 1/4A (male) conforming to ISO 228
Height72 mm
IP degree of protectionIP67 conforming to EN/IEC 60529 IP66 conforming to EN/IEC 60529
Local displayWithout
Materials in contact with fluidCeramic FPM PPS Stainless steel type AISI 303
Maximum permissible accidental pressure800 bar
Maximum switching current150 mA
Measurement accuracy+/- 1 % of the measuring range
Mechanical durability>= 10000000 cycles
NEMA degree of protectionNEMA 4
Operating positionAny position
Possible differential maximum at high setting380 bar
Possible differential minimum at high setting12 bar
Possible differential minimum at low setting12 bar
Pressure sensor nameXMLG
Pressure sensor size400 bar
Pressure sensor typeElectronic pressure sensor
Product certificationsCSA UL
Product or component typeElectronic pressure sensors
Product weight0.095 kg
Protection typeLoad short-circuit Reverse polarity
Protective treatmentTC
Quantity per setSet of 25
Range of productOsiSense XM
Repeat accuracy+/- 0.1 % of the measuring range
Resistance to conducted disturbances, induced by radio frequency fields30 V (0.15...80 Hz) conforming to EN/IEC 61000-4-6
Resistance to electromagnetic fields200 V/m (80...1000 Hz) conforming to EN/IEC 61000-4-3
Resistance to electrostatic discharge8 kV (on contact) conforming to EN/IEC 61000-4-2 15 kV (in air) conforming to EN/IEC 61000-4-2
Resistance to fast transients4 kV conforming to EN/IEC 61000-4-4
Resistance to magnetic fields30 A/m (50 Hz) conforming to EN/IEC 61000-4-8
Response time on output< 2 ms
RoHS (date code: YYWW)Compliant - since 0627 -  Schneider Electric declaration of conformity
SettingFactory setting
Shock resistance25 gn for 11 ms conforming to EN/IEC 60068-2-27
StandardsCE EN 50081-1 EN 50082-2 EN 61000-6-2 EN/IEC 60947-1 EN/IEC 60947-5-1
Surge withstand500 kV (12 Ohm) conforming to EN/IEC 61000-4-5 1 kV (42 Ohm) conforming to EN/IEC 61000-4-5
Sustainable offer statusNot Green Premium product
Type of output signalDiscrete
Type of packingGroup
Vibration resistance20 gn (f = 9...2000 Hz) conforming to EN/IEC 60028-2-6

Yderliger oplysninger: Se venligst SE katalog









©Schneider Electric A/S 2025

Katalog

Hjem Info