[Uimp] rated impulse withstand voltage | 0.5 kV |
[Us] rated supply voltage | 24 V DC, voltage limits: 8...33 V |
Ambient air temperature for operation | 0...80 °C |
Ambient air temperature for storage | -25...80 °C |
Analogue output function | 4...20 mA, 2-wire |
Controlled fluid | Fresh water 0...80 °C Air 0...80 °C |
Current consumption | < 20 mA |
Destruction pressure | 900 psi |
Diameter | 36 mm |
Drift of the sensitivity | +/- 0.04 % of measuring range/°K |
Drift of the zero point | +/- 0.03 % of measuring range/°K |
Electrical circuit type | Control circuit |
Electrical connection | 1 male connector M12 4 pins |
Electromagnetic compatibility | Immunity to magnetic fields conforming to EN/IEC 61000-4-8 - test level 30 A/m (f = 50 Hz) Radiated RF fields conforming to EN/IEC 61000-4-6 - test level 10 V (f = 0.15...80 MHz) 1.2/50 µs shock waves immunity test conforming to EN/IEC 61000-4-5 - test le |
Fluid connection type | 1/4" - 18 NPT (male) |
IP degree of protection | IP65 conforming to EN/IEC 60529 |
Length | 65.5 mm |
Local display | Without |
Materials in contact with fluid | Nitrile (NBR) Stainless steel type AISI 303 |
Maximum permissible accidental pressure | 600 psi |
Measurement accuracy | +/- 1 % of the measuring range |
Mechanical durability | >= 10000000 cycles |
NEMA degree of protection | NEMA 4 |
Operating position | Any position |
Pressure sensor name | XMLK |
Pressure sensor size | 300 psi |
Pressure sensor type | Pressure transmitter |
Pressure setting range | 0...300 psi |
Product certifications | CSA UL |
Product or component type | Electronic pressure sensors |
Product weight | 0.11 kg |
Protection type | Load short-circuit Reverse polarity |
Protective treatment | TC |
Quantity per set | Set of 25 |
Range of product | OsiSense XM |
REACh | Reference not containing SVHC above the threshold |
Repeat accuracy | +/- 0.3 % of the measuring range |
Response time on output | < 5 ms |
RoHS (date code: YYWW) | Compliant - since 1001 - Schneider Electric declaration of conformity |
Shock resistance | 25 gn for 11 ms conforming to EN/IEC 60068-2-27 |
Standards | CE EN 50081-1 EN 50082-2 EN 61000-6-2 EN/IEC 60947-1 EN/IEC 60947-5-1 |
Sustainable offer status | Not Green Premium product |
Type of output signal | Analogue |
Type of packing | Group |
Vibration resistance | 20 gn (f = 9...2000 Hz) conforming to EN/IEC 60068-2-6 |