[Ith] conventional free air thermal current | 12 A |
[Ui] rated insulation voltage | 300 V (degree of pollution: 2) conforming to IEC 60647-5-1, DIN VDE 0110 part 1 |
[Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to IEC 60647-5-1, DIN VDE 0110 part 1 |
[Us] rated supply voltage | 24 V DC (- 15...10 %) |
Ambient air temperature for operation | -25...55 °C |
Ambient air temperature for storage | -25...75 °C |
Antal tilhørende kredse | 0 |
Anvendelse af sikkerhedsmodul | For emergency stop and switch monitoring |
Brydeevne | 1.5 A at 24 V (DC-13) time constant: 50 ms for relæ udgang |
Brydeevne | B300: 360 VA, AC-15 (holding) B300: 3600 VA, AC-15 (inrush) |
Effektforbrug i W | <= 3 W |
Input protection type | Internal, electronic |
IP kapslingsklasse | 22-26 conforming to EN/IEC 60529 18-22 conforming to EN/IEC 60529 |
Lokal indikering | 3 LED |
Minimum udgangsspænding | 17 V for relæ udgang |
Minimum udgangsstrøm | 10 mA for relæ udgang |
Montagevejledning | 35 mm symmetrical DIN rail |
Navn pår sikkerhedsmodul | XPSABV |
Output thermal current | 6 A for instantaneous and time delay outputs |
Productcertificeringer | BG CSA UL |
Produkttype | Preventa safety module |
Range of product | Preventa Safety automation |
Responstid på indgangsafbrydelse | <= 200 ms |
Safety level | Can reach SILCL 2 conforming to EN/IEC 62061 time delay safety outputs Can reach SILCL 3 conforming to EN/IEC 62061 instantaneous safety outputs Can reach PL e/category 4 conforming to EN/ISO 13849-1 instantaneous safety outputs Can reach PL d/category 3 |
Safety reliability data | PFHd = 2E-7 1/h conforming to EN/IEC 62061 time delay safety outputs PFHd = 3E-8 1/h conforming to EN/IEC 62061 instantaneous safety outputs DC = 60...90 % conforming to EN/ISO 13849-1 time delay safety outputs DC > 99 % conforming to EN/ISO 13849-1 insta |
Standarder | EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 13850 |
Styrespænding | 24 V DC |
Synkroniseringstid mellem indgange | < 0.5 s |
Tidsforsinkelse | 0.15...3 s 1.5...30 s |
Tilhørende sikringsstørrelse | 6 A fuse type gG for instantaneous and time delay outputs |
Udgangstype | Relay time delay opening 1 NO, spændingsfri Relay instantaneous opening 2 NO, spændingsfri |
Vægt | 0.275 kg |
Tilslutningsklemmer | Spring terminals, removable terminal block Spring terminals, removable terminal block, clamping capacity: 2 x 0.5...2 x 1 mm² flexible cable with cable end, with double bezel Spring terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2. |