[EAA] effective aperture angle | +/- 5 ° at 3 m |
[Hp] Height protected | 310 mm |
[Ie] rated operational current | 2 A |
[R] Resolution | 30 mm |
[Sn] nominal sensing distance | 0...4 m by cabling 0...12 m by cabling |
[Us] rated supply voltage | 24 V DC (+/- 20 %) |
Ambient air temperature for operation | -10...55 °C 14...131 °F |
Ambient air temperature for storage | -25...70 °C -13...158 °F |
Current consumption | 900 mA with maximum load (receiver) 42 mA (transmitter) 83 mA no-load (receiver) 42 mA no-load (transmitter) |
Detection system | Transmitter-receiver system |
Device short name | XUSL2E |
Directives | 89/336/EEC - electromagnetic compatibility 2002/96/EC - WEEE directive 2002/95/EC - RoHS directive 98/37/EEC - machinery 89/655/EEC - work equipment |
Electrical connection | 1 male connector M12 8 pins (receiver) 1 male connector M12 5 pins (transmitter) |
Emission | IR LED (? = 950 nm) |
External Device Monitoring (EDM) | Selected by wiring |
Fixing mode | By fixing brackets |
Function available | LED display of operating modes and faults Muting through external safety module XPSLCMUT1160 Test |
Housing colour | RAL 3000 : red |
IP degree of protection | IP67 IP65 |
Kit composition | 1 user guide with certificate of conformity on CD-ROM 1 transmitter(s) 1 receiver(s) Adjustable mounting bracket(s) |
Local signalling | 2 dual colour LEDs (receiver) 1 multi-colour LED (transmitter) |
Marking | CE |
Material | End caps : polypropylene Front panel : polycarbonate Casing : aluminium |
Mission time | 20 yr |
Number of beams | 16 |
Offer type | Standard distance |
Optical characteristic | Resistance to light disturbance conforming to EN/IEC 61496-2 |
Output circuit type | DC |
Output current limits | 0.4 A for safety outputs OSSD |
Output type | 2 safety outputs OSSD solid-state PNP (integrated arc suppression) |
Output voltage | 24 V |
Product certifications | CE CULus TÜV |
Product end of life instructions | Available Download End of life manual |
Product environmental profile | Available Download Product environmental |
Product or component type | Safety light curtain type 2 |
Product specific application | For hand protection |
Product weight | 0.7 kg |
Range of product | Preventa Safety detection |
REACh | Reference not containing SVHC above the threshold |
Relative humidity | <= 95 % without condensation |
Response time | 6 ms |
RoHS (date code: YYWW) | Compliant - since 1425 - Schneider Electric declaration of conformity |
Safety level (correctly wired) | PL = d conforming to EN/ISO 13849-1 Category 2 conforming to EN/ISO 13849-1 SILCL 2 conforming to IEC 62061 SIL 2 conforming to IEC 61508 Type 2 conforming to IEC 61496-1 |
Safety reliability data | PFHd = 2.55E-8 1/h conforming to IEC 61508 |
Shock resistance | 10 gn for 16 ms conforming to IEC 61496-1 |
Supply | Power supply must meet requirements of IEC 60204-1 Power supply must meet requirements of IEC 61496-1 |
Sustainable offer status | Green Premium product |
Type of start / restart | Automatic Manual |
Voltage drop | <= 0.5 V |