[EAA] effective aperture angle | +/- 2.5 ° at 3 m |
[Hp] Height protected | 910 mm |
[Ie] rated operational current | 2 A |
[Sn] nominal sensing distance | 0...8 m by cabling 3...17 m by cabling |
[Us] rated supply voltage | 24 V DC (+/- 20 %) |
Ambient air temperature for operation | -25...55 °C -13...131 °F |
Ambient air temperature for storage | -25...70 °C -13...158 °F |
Current consumption | 900 mA with maximum load (receiver) 42 mA (transmitter) 83 mA no-load (receiver) 42 mA no-load (transmitter) |
Detection system | Transmitter-receiver system |
Device short name | XUSL4E |
Directives | 89/336/EEC - electromagnetic compatibility 2002/96/EC - WEEE directive 2002/95/EC - RoHS directive 98/37/EEC - machinery 89/655/EEC - work equipment |
Electrical connection | 1 male connector M12 8 pins (receiver) 1 male connector M12 5 pins (transmitter) |
Emission | IR LED (? = 950 nm) |
External Device Monitoring (EDM) | Selected by wiring |
Fixing mode | By fixing brackets |
Function available | Anti-condensation system LED display of operating modes and faults Muting through external safety module XPSLCMUT1160 Test |
Housing colour | RAL 3000 : red |
IP degree of protection | IP69K |
Kit composition | 1 PVC cable(s) Silicone o-ring(s) 1 user guide with certificate of conformity on CD-ROM 1 transmitter(s) 1 receiver(s) Adjustable mounting bracket(s) |
Local signalling | 2 dual colour LEDs (receiver) 1 multi-colour LED (transmitter) |
Marking | CE |
Material | Cable : PVC (polyvinyl chloride) Sealing plug : stainless steel AISI 316L Tube : PMMA (polymethyl methacrylate) |
Maximum Heating system power consumption | 10 W |
Mission time | 20 yr |
Number of beams | 4 |
Offer type | Long distance |
Ohmic cable resistance (per m) | 55.31 mOhm |
Optical characteristic | Resistance to light disturbance conforming to EN/IEC 61496-2 |
Output circuit type | DC |
Output current limits | 0.4 A for safety outputs OSSD |
Output type | 2 safety outputs OSSD solid-state PNP (integrated arc suppression) |
Output voltage | 24 V |
Product certifications | CE CULus TÜV |
Product end of life instructions | Available Download End of life manual |
Product environmental profile | Available Download Product environmental |
Product or component type | Safety light curtain type 4 |
Product specific application | For body protection |
Product weight | 4.66 kg |
Provided equipment | With heating system |
Range of product | Preventa Safety detection |
REACh | Reference not containing SVHC above the threshold |
Relative humidity | <= 95 % without condensation |
Response time | 3 ms |
RoHS (date code: YYWW) | Compliant - since 1425 - Schneider Electric declaration of conformity |
Safety level (correctly wired) | PL = e conforming to EN/ISO 13849-1 Category 4 conforming to EN/ISO 13849-1 SILCL 3 conforming to IEC 62061 SIL 3 conforming to IEC 61508 Type 4 conforming to IEC 61496-1 |
Safety reliability data | PFHd = 8.21E-9 1/h conforming to IEC 61508 |
Shock resistance | 10 gn for 16 ms conforming to IEC 61496-1 |
Space between beams | 300 mm |
Supply | Power supply must meet requirements of IEC 60204-1 Power supply must meet requirements of IEC 61496-1 |
Sustainable offer status | Green Premium product |
Type of cable | AWG 22 unshielded cable of 10 m |
Type of start / restart | Automatic Manual |
Vibration resistance | 0.35 +/- 0.05 mm (f = 10...55 Hz) conforming to IEC 61496-1 |