[Sn] nominal sensing distance | 40 m thru beam need a receiver |
[Us] rated supply voltage | 24...240 V AC/DC |
Add on input | Test by emission breaking |
Ambient air temperature for operation | -25...55 °C |
Ambient air temperature for storage | -40...70 °C |
Cable entry | 1 entry for M16 x 1.5 cable gland, cable outer diameter: 7...10 mm |
Current consumption | 20 mA (no-load) |
Delay first up | < 200 ms |
Delay recovery | < 25 ms |
Delay response | < 25 ms |
Depth | 77 mm |
Detection system | Thru beam |
Electrical connection | Screw-clamp terminals, 1 x 1.5 mm² or 1 x 0.75 mm² with adaptor |
Electrical durability | 500000 cycles, cos f = 1, 3000 cyc/mn 500000 cycles, cos f = 0.4, 500 cyc/mn |
Electronic sensor type | Photo-electric sensor transmitter |
Emission | Infrared thru beam |
Enclosure material | PBT |
Height | 92 mm |
IP degree of protection | IP67 double insulation conforming to IEC 60529 IP65 double insulation conforming to IEC 60529 |
Lens material | PMMA |
Material | Plastic |
Maximum sensing distance | 60 m thru beam |
Product certifications | CE CSA UL |
Product end of life instructions | Available Download End of life manual |
Product environmental profile | Available Download Product environmental |
Product specific application | - |
Product weight | 0.2 kg |
Range of product | OsiSense XU |
REACh | Reference not containing SVHC above the threshold |
RoHS (date code: YYWW) | Compliant - since 0914 - Schneider Electric declaration of conformity |
Sensor design | Compact 92 x 71 |
Sensor name | XUX |
Series name | General purpose multimode |
Setting-up | Without sensitivity adjustment |
Shock resistance | 30 gn (duration = 11 ms) conforming to IEC 60068-2-27 |
Status LED | 1 LED (green) for supply on |
Supply circuit type | AC/DC |
Supply voltage limits | 20...264 V AC/DC |
Sustainable offer status | Green Premium product |
Switching capacity in mA | 3 A (cos ? = 1 for 0.5 million cycles at 1 operating cycle per second at 250 V) 0.5 A (cos ? = 0.4 for 0.5 million cycles at 1 operating cycle per second at 250 V) |
Switching frequency | <= 20 Hz |
Time delay range | 0.02...15 s monostable, on-delay or off-delay (programmable) delay |
Vibration resistance | 7 gn, amplitude = +/- 1.5 mm (f = 10...55 Hz) conforming to IEC 60068-2-6 |
Voltage drop | <= 1.5 V (closed state) |
Width | 31 mm |
Wiring technique | 3-wire |