IP degree of protection | IP65 for contact housing conforming to NF C 20-010 IP65 for contact housing conforming to EN/IEC 60529 IP22 for enclosure conforming to NF C 20-010 IP22 for enclosure conforming to EN/IEC 60529 |
Light block supply | Direct |
Local signalling | With pilot light |
Marking | CE |
Mechanical durability | 10000 cycles |
Number of cables | 1 |
Overvoltage category | Class I conforming to NF C 20-030 Class I conforming to EN/IEC 61140 |
Positive opening | With conforming to EN/IEC 60947-5-1 |
Product or component type | Simple stop rope pull switch |
Product weight | 19.55 kg |
Protective treatment | TC |
Range of product | Preventa XY2 |
Reset | From inside enclosure |
Resistance across terminals | <= 25 MOhm conforming to NF C 93-050 method A <= 25 MOhm conforming to EN/IEC 60255-7 category 3 |
Short circuit protection | 10 A by gG cartridge fuse conforming to EN/IEC 60269 |
Standards | EN/IEC 60947-5-1 |
Terminals description ISO n°1 | (11-12)NC (13-14)NO |
Tightening torque | 0.8...1.2 N.m |
Trigger cable anchor point | RH side |
Trigger cable maximum length | 100 m |
[Ie] rated operational current | 1.2 A at 600 V AC-15, A600 conforming to EN/IEC 60947-5-1 appendix A 0.1 A at 600 V DC-13, Q600 conforming to EN/IEC 60947-5-1 appendix A |
[Ithe] conventional enclosed thermal current | 10 A |
[Ui] rated insulation voltage | 600 V (degree of pollution: conforming to CSA C22.2 No 14 500 V (degree of pollution: 3) conforming to EN/IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-1 |
[Us] rated supply voltage | 48 V |
Ambient air temperature for operation | -25...70 °C |
Ambient air temperature for storage | -40...70 °C |
Cable entry number | 1 tapped entry for Pg 13.5 cable gland |
Connections - terminals | Screw clamp terminal 1 x 0.5...2 x 1.5 mm² |
Contacts operation | Slow-break |
Contacts type and composition | 1 NC + 1 NO |
Device short name | XY2CB |
Distance between cable supports | 5 m |
Housing colour | Blue |