Navigér
Sœg

Wirenødstop XY2CB - RH & LH sides - 2NC


Varenr: XY2CB304
Produktet findes ikke i SAP!

[Ie] rated operational current1.2 A at 600 V AC-15, A600 conforming to EN/IEC 60947-5-1 appendix A 0.1 A at 600 V DC-13, Q600 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current10 A
[Ui] rated insulation voltage600 V (degree of pollution: conforming to CSA C22.2 No 14 500 V (degree of pollution: 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Cable entry number1 tapped entry for Pg 13.5 cable gland
Connections - terminalsScrew clamp terminal 1 x 0.5...2 x 1.5 mm²
Contacts operationSlow-break
Contacts type and composition2 NC
Device short nameXY2CB
Distance between cable supports5 m
Housing colourBlue
IP degree of protectionIP65 for contact housing conforming to NF C 20-010 IP65 for contact housing conforming to EN/IEC 60529 IP22 for enclosure conforming to NF C 20-010 IP22 for enclosure conforming to EN/IEC 60529
Local signallingWithout pilot light
MarkingCE
Mechanical durability10000 cycles
Number of cables2
Overvoltage categoryClass I conforming to NF C 20-030 Class I conforming to EN/IEC 61140
Positive openingWith conforming to EN/IEC 60947-5-1
Product end of life instructionsNeed no specific recycling operations
Product environmental profileAvailable Download Product environmental
Product or component typeSimple stop rope pull switch
Product weight29.25 kg
Protective treatmentTC
Range of productPreventa XY2
REAChReference not containing SVHC above the threshold
ResetFrom inside enclosure
Resistance across terminals<= 25 MOhm conforming to NF C 93-050 method A <= 25 MOhm conforming to EN/IEC 60255-7 category 3
RoHSCompliant - since 0920 -  Schneider Electric declaration of conformity
Short circuit protection10 A by gG cartridge fuse conforming to EN/IEC 60269
StandardsEN/IEC 60947-5-1
Sustainable offer statusGreen Premium product
Terminals description ISO n°1(11-12)NC (13-14)NO
Tightening torque0.8...1.2 N.m
Trigger cable anchor pointRH and LH sides
Trigger cable maximum length100 m

Yderliger oplysninger: Se venligst SE katalog









©Schneider Electric A/S 2025

Katalog