Wirenødstop XY2CE - RH side -1NC+1NO - key-release pushbutton


Varenr: XY2CE1A450EX
Produktet findes ikke i SAP!

[Ie] rated operational current0.27 A at 250 V DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A 3 A at 240 V AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current10 A
[Ui] rated insulation voltage300 V conforming to CSA C22.2 No 14 400 V, degree of pollution 3 conforming to EN/IEC 60947-1 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage4 kV
Ambient air temperature for operation-20...60 °C
Ambient air temperature for storage-40...70 °C
Auxiliary contacts operationSlow-break
Cable entry number2 plain hole with blanking plug 1 tapped entry (ISO M20) for cable gland
Class of protection against electric shockClass I conforming to NF C 20-030 Class I conforming to EN/IEC 61140
Connections - terminalsScrew clamp terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm²
Contacts type and composition1 NC + 1 NO
Depth105 mm
Device short nameXY2CE
Distance between cable supports10 m
Dust zoneZone 21 - 22
Height142 mm
Housing colourRed RAL 3000
IP degree of protectionIP65
Key number421
Local signallingWithout pilot light
MarkingII2 D-Ex tb IIIC T85°C Db IP65
Mechanical durability10000 cycles
Number of cables1
Positive openingWith, conforming to EN/IEC 60947-5-1 section 3
Product certificationsINERIS 04ATEX0015
Product end of life instructionsNeed no specific recycling operations
Product environmental profileAvailable Download Product environmental
Product or component typeLatching emergency stop trip wire switch
Protective treatmentTC
Range of productPreventa XY2
REAChReference not containing SVHC above the threshold
ResetBy key-release pushbutton
Resistance across terminals<= 25 MOhm conforming to NF C 93-050 method A <= 25 MOhm conforming to EN/IEC 60255-7 category 3
RoHS (date code: YYWW)Compliant - since 0931 -  Schneider Electric declaration of conformity
Safety levelCan reach SIL 3 conforming to EN/IEC 61508 Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-
Safety reliability dataB10d = 50000 value given for a life time of 20 years limited by mechanical or contact wear
Shock resistance50 gn for 11 ms conforming to EN/IEC 60068-2-27
Short circuit protection10 A cartridge fuse type gG conforming to EN/IEC 60269
StandardsATEX D 94/9/CE EN/IEC 60079-0 EN/IEC 60079-31
Sustainable offer statusGreen Premium product
Tightening torque0.8...1.2 N.m
Trigger cable anchor pointRH side
Trigger cable maximum length70 m
Vibration resistance10 gn (10...300 Hz) conforming to EN/IEC 60068-2-6