[Ie] rated operational current | 1.5 A at 240 V AC-15, B300 conforming to EN/IEC 60947-5-1 appendix A 0.1 A at 250 V DC-13, R300 conforming to EN/IEC 60947-5-1 appendix A |
[Ithe] conventional enclosed thermal current | 6 A |
[Ui] rated insulation voltage | 300 V (degree of pollution: conforming to CSA C22.2 No 14 300 V (degree of pollution: conforming to UL 508 400 V (degree of pollution: 3) conforming to EN/IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60947-1 |
Ambient air temperature for operation | -25...70 °C |
Ambient air temperature for storage | -40...70 °C |
Body material | Zamak |
Cable entry number | 3 tapped entry for 1/2" NPT conduit entry |
Connections - terminals | Screw clamp terminal 1 x 0.34...2 x 0.75 mm² Screw clamp terminal 1 x 0.34...1 x 1 mm² |
Contacts operation | Slow-break |
Contacts type and composition | 2 NC + 1 NO |
Cover material | Stainless steel |
Device short name | XY2CH |
Distance between cable supports | 5 m |
Housing colour | Red RAL 3000 |
IP degree of protection | IP65 for conforming to IEC 60529 |
Local signalling | Without pilot light |
Marking | CE |
Mechanical durability | 800000 cycles |
Number of cables | 1 |
Overvoltage category | Class I conforming to NF C 20-030 Class I conforming to EN/IEC 61140 |
Positive opening | With conforming to EN/IEC 60947-5-1 |
Product certifications | CCC for CSA for UL for category NISD emergency stop devices |
Product end of life instructions | Need no specific recycling operations |
Product environmental profile | Available |
Product or component type | Latching emergency stop rope pull switch |
Product weight | 0.865 kg |
Protective treatment | TC |
Range of product | Preventa XY2 |
REACh | Reference not containing SVHC above the threshold |
Reset | By flush pushbutton |
Resistance across terminals | <= 25 MOhm conforming to NF C 93-050 method A <= 25 MOhm conforming to EN/IEC 60255-7 category 3 |
RoHS | Compliant - since 1214 - Schneider Electric declaration of conformity |
Safety level | Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monito |
Safety reliability data | B10d = 4000000 with value given for a life time of 20 years limited by mechanical or contact wear conforming to IEC 60947-5-5 |
Shock resistance | 50 gn for 11 ms conforming to EN/IEC 60068-2-27 |
Short circuit protection | 6 A by gG cartridge fuse conforming to EN/IEC 60269 |
Standards | EN/IEC 60204-1 EN/IEC 60947-5-1 EN/IEC 60947-5-5 EN/ISO 13850 UL 508 Machinery directive 2006/42/EC CSA C22.2 No 14 Work equipment directive 2009/104/EC |
Sustainable offer status | Green Premium product |
Terminals description ISO n°1 | (13-14)NO (21-22)NC (31-32)NC |
Tightening torque | 0.8...1.2 N.m |
Trigger cable anchor point | RH or LH side |
Trigger cable maximum length | 30 m |
Vibration resistance | 10 gn (f = 10...150 Hz) conforming to EN/IEC 60068-2-6 |