Navigér
Sœg

Wirenĝdstop XY2CH - 1NC+1NO - meterushroom hoved pushbutton


Varenr: XY2CH13350H29
Produktet findes ikke i SAP!

[Ie] rated operational current0.27 A at 250 V DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A 3 A at 240 V AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current10 A
[Ui] rated insulation voltage300 V (degree of pollution: conforming to CSA C22.2 No 14 300 V (degree of pollution: conforming to UL 508 500 V (degree of pollution: 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
Ambient air temperature for operation-25...70 °C
Ambient air temperature for storage-40...70 °C
Body materialZamak
Cable entry number3 tapped entry for ISO M20 cable gland
Connections - terminalsScrew clamp terminal 1 x 0.5...2 x 1.5 mm²
Contacts operationSlow-break
Contacts type and composition1 NC + 1 NO
Cover materialStainless steel
Device short nameXY2CH
Distance between cable supports5 m
Housing colourRed RAL 3000
IP degree of protectionIP65 for conforming to IEC 60529
Local signallingWithout pilot light
MarkingCE
Mechanical durability800000 cycles
Number of cables1
Overvoltage categoryClass I conforming to NF C 20-030 Class I conforming to EN/IEC 61140
Positive openingWith conforming to EN/IEC 60947-5-1
Product certificationsCCC for
Product or component typeLatching emergency stop rope pull switch
Product weight0.9 kg
Protective treatmentTC
Range of productPreventa XY2
ResetBy mushroom head pushbutton
Resistance across terminals<= 25 MOhm conforming to NF C 93-050 method A <= 25 MOhm conforming to EN/IEC 60255-7 category 3
Safety levelCan reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monito
Safety reliability dataB10d = 4000000 with value given for a life time of 20 years limited by mechanical or contact wear conforming to IEC 60947-5-5
Shock resistance50 gn for 11 ms conforming to EN/IEC 60068-2-27
Short circuit protection10 A by gG cartridge fuse conforming to EN/IEC 60269
StandardsEN/IEC 60204-1 EN/IEC 60947-5-1 EN/IEC 60947-5-5 EN/ISO 13850 Machinery directive 2006/42/EC Work equipment directive 2009/104/EC
Terminals description ISO n°1(13-14)NO (21-22)NC
Tightening torque0.8...1.2 N.m
Trigger cable anchor pointRH or LH side
Trigger cable maximum length30 m
Vibration resistance10 gn (f = 10...150 Hz) conforming to EN/IEC 60068-2-6

Yderliger oplysninger: Se venligst SE katalog









©Schneider Electric A/S 2025